About WARNING of ibischk2

From: Akihiro Takegama <tkgm@mario.tdc.tijp.ti.com>
Date: Mon Apr 06 1998 - 06:34:39 PDT

  Chris,
    I'm sorry. I would like to cofirm my opinion, and I have one question.

   [1] Is slope of V(R) of <Fig 1> based on V(R) of <Fig 2>, isn't it ?

      <Fig 1> <Fig 2>
                       [Pulldown] + [GNDclamp] --- Vcc ---
       (I) or [POWERclamp] ^ ^
           | * | | |
     0.6A x **** | | |
           | x ** |-+ | I | V (Pch)
           | x * +--o|| | |
           | * | |-+ +------+ |
           | * ^ x L | | | V
           | * | x slope = -50 Ohm --+ +------+ | ----
           | * | x | | | V ^
           *--------|-----------x--------- | |-+ < |
         0.0V | 3.3 (V) +---|| < 50 | V (R)
                            (V_fixture) |-+ < Ohm |
           |<------>|<--------->| | | V
             V(Pch) V (R) --- --- ---
                                                             /// /// ///

   [2] Could you tell me the reason why it is 2% ?
      Is this must value ?
       ( You decided the value on Oct. in 1996. )
       If we decided the diode value, the value is lower the IV curve (leak).

      We have the IBIS check problem yet. The last warning disappeared by your
     cooperation.
      The max voltage value can't be up 2.81V. ( Below is in 3% margin )
  ----------------------------------------------------------------------------
  WARNING - Model 'inout': MAX AC Falling Endpoints (-0.00V, 2.73V) not within
          0.055V (2%) of ( 0.00V, 2.81V) on VI curves for 50 Ohms to 0V
  ----------------------------------------------------------------------------

 - Regards,
    A.Takegama ( tkgm@tdc.tijp.ti.com )

    ************************************
    * Name : Akihiro Takegama *
    * E-mail : tkgm@tdc.tijp.ti.com *
    * Corp. : Texas Instruments *
    ************************************
- -----------------------------------------------------------------------

- ------- Start of forwarded message -------
Sender: crokusek@qdt.com
Date: Wed, 01 Apr 1998 09:21:51 -0800
From: Chris Rokusek <crokusek@qdt.com>
Organization: Quad Design Technology
X-Mailer: Mozilla 3.01 (X11; I; SunOS 4.1.4 sun4m)
Mime-Version: 1.0
To: Akihiro Takegama <tkgm@mario.tdc.tijp.ti.com>
Cc: ibis-users@vhdl.org
Subject: Re: [Re: About WARNING of ibischk2]
References: <199804010915.SAA15589@mario.tdc.tijp.ti.com>
Content-Type: text/plain; charset=us-ascii
Content-Transfer-Encoding: 7bit

Akihiro,

The "LOW" curve used in the DC vs. AC test is the sum of BOTH shunt
curves (POWER_Clamp/GND_Clamp) + the Pulldown Curve.

Similarly the "HIGH" curve used in the test is the sum of BOTH shunt
curves + Pullup Curve.

Chris

Akihiro Takegama wrote:
>
> Chris,
> thank you very much for your quick response and answer.
>
> I would like to confirm my issue.
>
> # Is it crosspoint 50 Ohm slope against the value of [Pulldown]
> + [Gndclamp] ?
>
>
> (I)
> | * [Pulldown] + [GNDclamp]
> 0.6A x ****
> | x **
> | x *
> | *
> | * ^ x
> | * | x slope = 50 Ohm
> | * | x
> *--------|-----------x---------
> 0.0V | 3.0 V (V)
> (0.95V)
> #####
>
> - Regards,
> A.Takegma
> > ************************************
> > * Name : Akihiro Takegama *
> > * E-mail : tkgm@tdc.tijp.ti.com *
> > * Corp. : Texas Instruments *
> > ************************************
>
> -----------------------------------------------------------------------
> ------- Start of forwarded message -------
> Sender: crokusek@qdt.com
> Date: Tue, 31 Mar 1998 10:01:46 -0800
> From: Chris Rokusek <crokusek@qdt.com>
> Organization: Quad Design Technology
> X-Mailer: Mozilla 3.01 (X11; I; SunOS 4.1.4 sun4m)
> Mime-Version: 1.0
> To: Akihiro Takegama <tkgm@mario.tdc.tijp.ti.com>
> Cc: ibis-users@vhdl.org
> Subject: Re: About WARNING of ibischk2
> References: <199803311308.WAA12838@mario.tdc.tijp.ti.com>
> Content-Type: text/plain; charset=us-ascii
> Content-Transfer-Encoding: 7bit
>
> Akihiro,
>
> The ibishk2 program is checking the first and last point of your Rising
> and Falling AC Waveforms against the DC VI curves and given test load
> (50 Ohms).
>
> For your case the message indicates that the first point given in the
> Rising Waveform table is .74V.
>
> If you were to plot the intersection of a 50 Ohm to 3V load line (slope
> = 50 V/I) and the given DC VI curve you would see that they interesect
> at .95V (this is fist value in [3] below).
>
> So since
>
> abs(.95 - .74) > 2% * (3 - .74)
> .21 > .045
>
> The checker will print a warning.
>
> The reason for the check is that the first and last points of the AC
> waveforms are supposed to be the stable DC value when driving the given
> load.
>
> Chris Rokusek
> Viewlogic
>
> Akihiro Takegama wrote:
> >
> > To: IBIS-users,
> >
> > Hello, I'm making the IBIS model. But I am confused at ibischk.
> > Could you support me ?
> >
> > I have one question.
> >
> > 1 ) I made the IBIS model within "Rising Waveform" and "Falling
> > Waveform" and I ran the ibischk2. But many warning appeares
> > it's IBIS model, which like as below.
> > Could you please tell me how to calculate the value [3]. ?
> >
> > - ----------------------------------------------------------------------------
> > WARNING - Model 'inout': MIN AC Rising Endpoints ( 0.74V, 3.00V) not within
> > -------------
> > [1]
> >
> > 0.045V (2%) of ( 0.95V, 3.00V) on VI curves for 50 Ohms to 3V
> > ----------- ----------------
> > [2] [3]
> > - -----------------------------------------------------------------------------
> >
> > - Regards,
> > A.Takegama
> >
> > ************************************
> > * Name : Akihiro Takegama *
> > * E-mail : tkgm@tdc.tijp.ti.com *
> > * Corp. : Texas Instruments *
> > ************************************
> > ------- End of forwarded message -------
Received on Mon Apr 6 06:38:21 1998

This archive was generated by hypermail 2.1.8 : Fri Jun 03 2011 - 09:53:46 PDT