Re: Built-in model Termination.

From: Bob Ross <bob_ross@mentorg.com>
Date: Thu Jan 20 2000 - 13:54:45 PST

Chris:

IBIS Version 3.2 supports the [R Series] keyword and series
element constructs that would allow you to put a resistor
across a differential port. You need to check with the
simulation vendors regarding whether this feature is
supported in their products.

Bob Ross
Mentor Graphics

Chris Potts wrote:
>
> I would like to know if it is possible to add a "built-in" termination
> resistor between two pins in an IBIS model text file, i.e. say 50 Ohms
> between pins 1 and 2 on a differential receiver port?
>
> Can this be done using a resistance Matrix at the end of the model??
>
> Any help would be very much appreciated, thanks in advance.
>
> Regards
>
> Chris Potts.
>
> Mr Chris Potts BEng(Hons).
> Design Engineer
> PowerX Ltd
> Tel: +44 0161 286 2000 ext 201
> Fax: +44 0161 286 2202
> E-Mail: chrisp@px.uk.com
Received on Thu Jan 20 13:56:23 2000