RE: zero risetime in the IBIS model

From: <Aubrey_Sparkman@Dell.com>
Date: Wed Apr 04 2001 - 11:44:57 PDT

Jason,
Yes, I have seen a simulator go nuts and produce a very strange meaningless
waveform. Problem went away when the [Ramp] data was corrected.

ramp data matching the VT data means that they should agree, both come from
time-based data, perhaps even the same load.

From a purist point of view, I'm not an IBIS expert and I don't want to
change the data my supplier gives me. But if your boss wants results NOW
with your best GUESS, as another suggested, you can build your own Ramp data
from the V/T data. Use the Rising Waveform for the dV/dt_r (R_fixture to
ground if there are two). Use the Falling Waveform for the dV/dt_f
(R_fixture to V_fixtuer if there are two).
dV=0.6*(Vmax-Vmin)
dt_x is the difference in time between the 20% and 80% voltage points.

Good Luck!

Aubrey Sparkman
Signal Integrity
Aubrey_Sparkman@Dell.com
(512) 723-3592

> -----Original Message-----
> From: Jason Leung [mailto:jleung@cid.alcatel.com]
> Sent: Wednesday, April 04, 2001 10:36 AM
> To: Aubrey_Sparkman@exchange.dell.com
> Cc: Adam.Tambone@fairchildsemi.com; ibis-users@eda.org
> Subject: Re: zero risetime in the IBIS model
>
>
> Hi Aubrey Sparkman:
> So even though the translator doesn't complain about the zero
> rise time in the
> driver model, the translator will go "nuts" ehh? So the
> waveform come after
> the simulation will have no meaning ehh?
> what do you mean by" ramp data match the VT data"?
> thanks alot
> Jason Leung
>
>
> > Jason,
> > Even if your simulator's translator doesn't complain, your
> simulator may go
> > nuts and give VERY "interesting" results. Go back to your
> supplier and
> > insist that the ramp data match the VT data.
> >
> > Aubrey Sparkman
> > Signal Integrity
> > Aubrey_Sparkman@Dell.com
> > (512) 723-3592
> >
> > > -----Original Message-----
> > > From: Adam.Tambone@fairchildsemi.com
> > > [mailto:Adam.Tambone@fairchildsemi.com]
> > > Sent: Wednesday, April 04, 2001 9:18 AM
> > > To: ibis-users@eda.org
> > > Subject: Re: zero risetime in the IBIS model
> > >
> > >
> > > Jason,
> > >
> > > I'm not sure what translator you are using but the
> > > HSPICE translator
> > > will by default use ramp data for determining switching
> > > characteristics in
> > > DC and transient analysis. You can specify that the
> > > translator use the
> > > rising and falling waveform data instead. See Chapter 18 of
> > > the Avanti
> > > HSPICE User's Manual.
> > >
> > > Adam Tambone
> > > Fairchild Semiconductor
> > >
> > >
> > >
> > > Hi everyone:
> > > I am trying to verify a IBIS model which consists of a
> zero rise time
> > > for the driver:
> > > | variable typ min max
> > > dV/dt_r 0/0 0/0 0/0
> > > dV/dt_f 2.0448/0.4029n 1.8546/0.4176n
> > > 2.1792/0.4102n
> > > R_load = 50.0000
> > >
> > > My question is :does anyone know how the IBIS translator
> > > going to handle
> > > this situation??
> > > thanks alot
> > > Best Regards
> > > Jason Leung
> > >
> > >
>

 

Received on Wed Apr 4 11:47:58 2001