[IBIS] [IBIS-Users] WARNING Endpoint

From: Fabio BRINA <fabio.brina_at_.....>
Date: Fri Jan 20 2006 - 06:55:44 PST
Hi  IBIS experts,

when I check  my  IBIS  model  I  optain  these warning:

WARNING - Model 'mod_out': TYP AC Rising Endpoints ( 0.00V,  4.97V) not 
within
          0.099V (2%) of ( 3.11V,  3.94V) on VI curves for 1000 Ohms to 0V
WARNING - Model 'mod_out': TYP AC Falling Endpoints ( 0.02V,  5.00V) not 
within
          0.100V (2%) of ( 3.14V,  3.96V) on VI curves for 1000 Ohms to 5V

I  know  what it means,  but  I  don't know if  I  have  to modify
the  R_fixture to  eliminate it ( I fix R_fix=1k from the datasheet ).
morever in some IBIS editor this  Warning became an Error !
so  I  don't know if is an acceptable Warning.
( I use s2ibis2 v.2.1 )

What  do you think about?

many  thanks


Another type of question:
About IBIS Summit ( DATE 06 ), there is an expiry date to register on them?

thanks again.

Fabio.





-----------------------------------------------------------------
|For help or to subscribe/unsubscribe, email majordomo@eda.org
|with the appropriate command message(s) in the body:
|
|  help
|  subscribe   ibis       <optional e-mail address, if different>
|  subscribe   ibis-users <optional e-mail address, if different>
|  unsubscribe ibis       <optional e-mail address, if different>
|  unsubscribe ibis-users <optional e-mail address, if different>
|
|or email a request to ibis-request@eda.org.
|
|IBIS reflector archives exist under:
|
|  http://www.eda.org/pub/ibis/email_archive/  Recent
|  http://www.eda.org/pub/ibis/users_archive/  Recent
|  http://www.eda.org/pub/ibis/email/          E-mail since 1993
Received on Fri Jan 20 07:06:08 2006

This archive was generated by hypermail 2.1.8 : Fri Jan 20 2006 - 07:10:24 PST