[IBIS-Users] IBIS website (Question, Internal 100 Ohms termination)


Subject: [IBIS-Users] IBIS website (Question, Internal 100 Ohms termination)
From: Syed Huq (shuq@cisco.com)
Date: Thu May 01 2003 - 11:12:59 PDT


------------- Begin Forwarded Message -------------

From: Gustavo Blando <gblando@axiowave.com>
To: "'shuq@cisco.com'" <shuq@cisco.com>
Subject: IBIS website (Question, Internal 100 Ohms termination)
Date: Thu, 1 May 2003 14:05:36 -0400
MIME-Version: 1.0

I would like to ask a question for an IBIS specification. I am not sure if
I am sending this email to the right place, if not please advise where it
should be sent.

Hello, if I have an internal 100 Ohms termination in my receiver between P
and N.
How is the appropriate way to model that in IBIS.
Please advise off different alternatives.

Thanks.

This is what I tried, but it did not work, It says this
ERROR - Component 'XXXX': [Series Pin Mapping] Pin2 '17': model type cannot
be Series or Series_switch.

[Pin] signal_name model_name R_pin L_pin C_pin
|
16 CLK1 Z630781_IN4 .174 3.79n .41p
17 _CLK1 Z630781_IN4 .171 3.6n .37p
|
[Diff Pin] inv_pin vdiff tdelay_typ tdelay_min tdelay_max
|
16 17 800mv NA NA NA
|

[Series Pin Mapping] pin_2 model_name
16 17 Series_100
|
[Model] Z630781_IN4
Model_type Input_ECL
Vinl = 1.657V
Vinh = 2.277V
C_comp 3.000pF NA NA
|
| variable typ min max
[Voltage Range] 3.300V NA NA
[GND Clamp Reference] 0.000V NA NA
[POWER Clamp Reference] 3.300V NA NA
|
[GND Clamp]
|
-3.300V -513.0mA NA NA
-1.054V -44.40mA NA NA
-912.0mV -20.00mA NA NA
-811.0mV -7.000mA NA NA
-750.0mV -2.300mA NA NA
-709.0mV -800.0uA NA NA
-669.0mV -200.0uA NA NA
-334.5mV 0.000A NA NA
1.449V 0.000A NA NA
6.600V 250.3uA NA NA
|
[POWER Clamp]
|
6.600V 0.000A NA NA
-326.7mV 0.000A NA NA
-490.0mV 86.25uA NA NA
-561.0mV 86.25uA NA NA
-632.0mV 179.3uA NA NA
-693.0mV 179.3uA NA NA
-754.0mV 473.4uA NA NA
-795.0mV 1.271mA NA NA
-835.0mV 3.069mA NA NA
-936.0mV 12.36mA NA NA
-1.038V 26.06mA NA NA
-3.300V 400.2mA NA NA
|

[Model] Series_100
Model_type Series
C_comp 0 0 0
|
[Voltage Range] 3.3 3.1 3.6
[R series] 100 86 120

Gus

Gustavo Blando
Axiowave Networks
Tel: (774) 348-4784
Fax: (774) 348-4008
email: gblando@axiowave.com

------------- End Forwarded Message -------------

|------------------------------------------------------------------
|For help or to subscribe/unsubscribe, email majordomo@eda.org
|with just the appropriate command message(s) in the body:
|
| help
| subscribe ibis <optional e-mail address, if different>
| subscribe ibis-users <optional e-mail address, if different>
| unsubscribe ibis <optional e-mail address, if different>
| unsubscribe ibis-users <optional e-mail address, if different>
|
|or email a written request to ibis-request@eda.org.
|
|IBIS reflector archives exist under:
|
| http://www.eda.org/pub/ibis/email_archive/ Recent
| http://www.eda.org/pub/ibis/users_archive/ Recent
| http://www.eda.org/pub/ibis/email/ E-mail since 1993



This archive was generated by hypermail 2b28 : Thu May 01 2003 - 11:18:22 PDT