[IBIS-Users]Difference in rise-fall waveform due to c_comp!!


Subject: [IBIS-Users]Difference in rise-fall waveform due to c_comp!!
From: Alok Rungta (a0875973@india.ti.com)
Date: Tue Mar 02 2004 - 08:56:41 PST


Hello IBIS users,

I am trying to understand how the simulation tool is using the c_comp
parameter in the ibis model. For the same ibis model i just change the
c_comp parameter and resimulated to see if there are any differences in
the observed output voltage waveform. When using a cap as a load I see
differences in both the rise and the fall transition .. but when using
a pure resistive load I find that both the models on simulation give the
same rise waveform but different fall waveforms. Is this the expected
behavior ?? Isnt c_comp supposed to be used only in case of reflection ??

Thanks in Anticipation
Alok Rungta

|------------------------------------------------------------------
|For help or to subscribe/unsubscribe, email majordomo@eda.org
|with just the appropriate command message(s) in the body:
|
| help
| subscribe ibis <optional e-mail address, if different>
| subscribe ibis-users <optional e-mail address, if different>
| unsubscribe ibis <optional e-mail address, if different>
| unsubscribe ibis-users <optional e-mail address, if different>
|
|or email a written request to ibis-request@eda.org.
|
|IBIS reflector archives exist under:
|
| http://www.eda.org/pub/ibis/email_archive/ Recent
| http://www.eda.org/pub/ibis/users_archive/ Recent
| http://www.eda.org/pub/ibis/email/ E-mail since 1993



This archive was generated by hypermail 2b28 : Tue Mar 02 2004 - 09:26:56 PST