[IBIS-Users] Fork-Endfork in IBIS EBD Models

From: <mhaque_at_.....>
Date: Fri Dec 30 2005 - 13:33:13 PST
Hi All,
When creating IBIS EBD model for multi die package, is multiple fork and
endfork statement allowed for one main branch? For example if the device
has 4 die and from each pad bondwires are connected to one external ball
is it okay to describe the path description as below?

Note the last fork-endfork statement. Is it necessary that the original
path needs to be continued and therefore the path description has to end
with a series path? 

[Path Description] QUAD_DIE_SIGNAL
A1
Len=0 R=16.646m L=1.406n C=0.456p /      |Substrate R, L and C 

Fork
Len=0 R=10m L=1nH C=1p /             |Bondwire r,l,c from pin A1 to U1,
pad #21
Endfork
Node U1.21

Fork
Len=0 R=10m L=1nH C=1p /             |Bondwire r,l,c from pin A1 to U2,
pad #21
Endfork
Node U2.21

Fork 				|Bondwire r,l,c from pin A1 to U3, pad
#21
Len=0 R=10m L=1nH C=1p 
Endfork 
Node U3.21

Fork 				|Bondwire r,l,c from pin A1 to U4 , pad
#21
Len=0 R=10m L=1nH C=1p 
Endfork 
Node U4.21

Best Regards
Moshiul Haque
Micron Technology Inc.

|------------------------------------------------------------------
|For help or to subscribe/unsubscribe, email majordomo@eda.org
|with just the appropriate command message(s) in the body:
|
|  help
|  subscribe   ibis       <optional e-mail address, if different>
|  subscribe   ibis-users <optional e-mail address, if different>
|  unsubscribe ibis       <optional e-mail address, if different>
|  unsubscribe ibis-users <optional e-mail address, if different>
|
|or email a written request to ibis-request@eda.org.
|
|IBIS reflector archives exist under:
|
|  http://www.eda.org/pub/ibis/email_archive/  Recent
|  http://www.eda.org/pub/ibis/users_archive/  Recent
|  http://www.eda.org/pub/ibis/email/          E-mail since 1993
Received on Fri Dec 30 13:33:20 2005

This archive was generated by hypermail 2.1.8 : Fri Dec 30 2005 - 13:38:35 PST