RE: [IBIS-Users] question about IBIS simulation for a complete inverter

From: Tom Dagostino <tom@teraspeed.com>
Date: Wed Mar 17 2010 - 09:17:01 PDT

Ji

 

Historically IBIS Signal Integrity simulators are not designed to simulate
the transfer function of the parts in the nets you are simulating, they only
concern themselves with the interaction of the I/O buffers and the
transmission line medium that is between them. There is no description of
the logic function, delay or any of the other requirements that may be
needed to generate the timing of signals from input to output in an IBIS
model. There are some timing simulators that do at least some level of
input to output simulation.

 

Tom Dagostino
Teraspeed(R) Labs
13610 SW Harness Lane
Beaverton, OR 97008
503-430-1065

503-430-1285 FAX
tom@teraspeed.com
www.teraspeed.com

Teraspeed Consulting Group LLC
121 North River Drive
Narragansett, RI 02882
401-284-1827

 

From: owner-ibis-users@eda.org [mailto:owner-ibis-users@eda.org] On Behalf
Of ji xiao
Sent: Wednesday, March 17, 2010 8:06 AM
To: ibis-users@eda.org
Subject: [IBIS-Users] question about IBIS simulation for a complete inverter

 

Dear Sir/Madam,

As a beginner worked with IBIS model, I met a problem about the IBIS
simulation for a complete device. Let's take an inverter as an example. If I
want to model a complete inverter including the transfer function by using
IBIS, do I just need to simulate the output model only(i.e. does the output
model contain the transfer function) ? or cascade IBIS input model with
output model?
If we need to cascade them, does that mean just to receive the output signal
of the input model as the input signal of the output model?
 
Thanks and regards,
Ji Yuancheng

-- 
This message has been scanned for viruses and 
dangerous content by  <http://www.mailscanner.info/> MailScanner, and is 
believed to be clean. 
-- 
This message has been scanned for viruses and
dangerous content by MailScanner, and is
believed to be clean.
--------------------------------------------------------------------
|For help or to subscribe/unsubscribe, e-mail majordomo@eda-stds.org
|with the appropriate command message(s) in the body:
|
|  help
|  subscribe   ibis       <optional e-mail address, if different>
|  subscribe   ibis-users <optional e-mail address, if different>
|  unsubscribe ibis       <optional e-mail address, if different>
|  unsubscribe ibis-users <optional e-mail address, if different>
|
|or e-mail a request to ibis-request@eda-stds.org.
|
|IBIS reflector archives exist under:
|
|  http://www.eda-stds.org/pub/ibis/email_archive/ Recent
|  http://www.eda-stds.org/pub/ibis/users_archive/ Recent
|  http://www.eda-stds.org/pub/ibis/email/         E-mail since 1993
Received on Wed Mar 17 09:22:52 2010

This archive was generated by hypermail 2.1.8 : Wed Mar 17 2010 - 09:23:25 PDT