RE: [IBIS-Users] Composite Current and ISOO - Is it really enable accurate SSN ?

From: Syed Huq (huqs) <huqs@cisco.com>
Date: Tue Jun 29 2010 - 09:01:10 PDT

Hi Sergey,

I am not aware of any EDA tools that have implemented these new features
of 5.0. As an end user of IBIS, the expectation would be that tools that
support these keywords could be used to test out models generated by the
model developers.

If any EDA tools does support these, pls speak up.

Tks
Syed

-----Original Message-----
From: owner-ibis-users@eda.org [mailto:owner-ibis-users@eda.org] On
Behalf Of Nikonchuk Sergey-R6294C
Sent: Tuesday, June 29, 2010 7:36 AM
To: ibis-users@eda.org
Subject: [IBIS-Users] Composite Current and ISOO - Is it really enable
accurate SSN ?

Hi All,
A time ago was several presentations, IEEE articles related to
improvement of IBIS models to enable
Accurate Power Integrity modeling.

As a results, two new kewords were introduced in IBIS 5.0 standard -
Composite Current and ISSO_PU/PD.

Since that - I didn't find any presentation and/or article that proove
new approach
And confirm accuracy level of simulation with new data.
As well, I don't know any IBIS simulator that really support these
keyword.

Does it mean that new keyword does not provide real advantage as was
expected?
Can anybody share some simulation results with new keywords?
 -- Or Point me on IBIS simulator that support it?
    -- Or Simulation Models Implementation that support new data?

Feel free to e-mail me directly if there is some concerns with
information distribution in this mail list.

Any information, comments would be highly appreciated.

Thanks,
Sergey.

Sergey.Nikonchuk@freescale.com

-- 
This message has been scanned for viruses and
dangerous content by MailScanner, and is
believed to be clean.
--------------------------------------------------------------------
|For help or to subscribe/unsubscribe, e-mail majordomo@eda-stds.org
|with the appropriate command message(s) in the body:
|
|  help
|  subscribe   ibis       <optional e-mail address, if different>
|  subscribe   ibis-users <optional e-mail address, if different>
|  unsubscribe ibis       <optional e-mail address, if different>
|  unsubscribe ibis-users <optional e-mail address, if different>
|
|or e-mail a request to ibis-request@eda-stds.org.
|
|IBIS reflector archives exist under:
|
|  http://www.eda-stds.org/pub/ibis/email_archive/ Recent
|  http://www.eda-stds.org/pub/ibis/users_archive/ Recent
|  http://www.eda-stds.org/pub/ibis/email/         E-mail since 1993
-- 
This message has been scanned for viruses and
dangerous content by MailScanner, and is
believed to be clean.
--------------------------------------------------------------------
|For help or to subscribe/unsubscribe, e-mail majordomo@eda-stds.org
|with the appropriate command message(s) in the body:
|
|  help
|  subscribe   ibis       <optional e-mail address, if different>
|  subscribe   ibis-users <optional e-mail address, if different>
|  unsubscribe ibis       <optional e-mail address, if different>
|  unsubscribe ibis-users <optional e-mail address, if different>
|
|or e-mail a request to ibis-request@eda-stds.org.
|
|IBIS reflector archives exist under:
|
|  http://www.eda-stds.org/pub/ibis/email_archive/ Recent
|  http://www.eda-stds.org/pub/ibis/users_archive/ Recent
|  http://www.eda-stds.org/pub/ibis/email/         E-mail since 1993
Received on Tue Jun 29 09:01:24 2010

This archive was generated by hypermail 2.1.8 : Tue Jun 29 2010 - 09:01:54 PDT