[IBIS-Users] RE: Role of C_comp

From: Muranyi, Arpad <Arpad_Muranyi@mentor.com>
Date: Tue Sep 03 2013 - 23:45:48 PDT
Ling Li,

It seems that your conclusion from reading Todd Westerhoff's email
in the link you provided is not quite correct.  Todd seems to say
(correctly) that the output waveform of a driver will not change
when C_comp is changed in the IBIS [Model].  You should only see
differences in the waveforms when a reflection hits the driver
and that reflection bounces back off of the driver.  This secondary
reflection from the driver should depend on the C_comp value.

Similarly, if an I/O buffer model is in the receive mode (i.e. input
state), you should see different waveforms when you change the C_comp
value.

As far as I can tell from my days when I worked at Intel and used
HSPICE in my work, HSPICE does what I described above correctly.

Now that I work for Mentor, I can also tell you that the results
of HyperLynx are correct the same way.  I am actually surprised to
hear that you see different results.  Are you sure your test case
is designed well to show and observe these effects correctly?

By the way, the latest HyperLynx version is now 9.0 (not 8.2.1).

I hope this helps answering your question.

Thanks,

Arpad
=======================================================================

From: owner-ibis-users@eda.org [mailto:owner-ibis-users@eda.org] On Behalf Of Ling Li Ong
Sent: Wednesday, September 04, 2013 12:47 AM
To: ibis-users@eda.org
Cc: Siong Hee Lim
Subject: [IBIS-Users] Role of C_comp

Hi,

I saw some discussions on c_comp issue at user archive at link:
http://www.eda.org/ibis/users_archive/0487.html

I am confused by the c_comp whether it is double-counted and the different result obtained when using different tools.
According to the comment in the link above, varying the c_comp may see the changes in rise/fall curve.  This is definitely true when using the HSPICE simulator.  But, if you using the latest Hyperlynx  version 8.2.1, changing the c_comp will not reflect the changes in rise/fall curve.

Can you please advise which tools are showing the correct response on c_comp when sweeping at different value?
Thanks.

Regards,
Ling Li






________________________________
Confidentiality Notice.
This message may contain information that is confidential or otherwise protected from disclosure. If you are not the intended recipient, you are hereby notified that any use, disclosure, dissemination, distribution, or copying of this message, or any attachments, is strictly prohibited. If you have received this message in error, please advise the sender by reply e-mail, and delete the message and any attachments. Thank you.

--
This message has been scanned for viruses and
dangerous content by MailScanner<http://www.mailscanner.info/>, and is
believed to be clean.

-- 
This message has been scanned for viruses and
dangerous content by MailScanner, and is
believed to be clean.


--------------------------------------------------------------------
|For help or to subscribe/unsubscribe, e-mail mikelabonte@eda-stds.org
|or ibis-request@eda-stds.org
|
|IBIS reflector archives exist under:
|
|  http://www.eda-stds.org/ibis/email_archive/ Recent
|  http://www.eda-stds.org/ibis/users_archive/ Recent
|  http://www.eda-stds.org/ibis/email/         E-mail since 1993
Received on Tue Sep 3 23:46:02 2013

This archive was generated by hypermail 2.1.8 : Tue Sep 03 2013 - 23:46:16 PDT