Hello all,

A short question regarding interpretation of a model:

In the IBIS 2.1 spec, the ramp rate is defined as

  dV 20% to 80% voltage swing
  -- = --------------------------------------
  dt Time to take to swing the above voltage

 
When I scan through a random set of IBIS models, I see the
following entries after the [Ramp] keyword of the following
types:

a) dV/dt_r 1.84/0.65n 1.77/0.65n 1.87/0.53n

b) dV/dt_r 4.1/1n 1.6/1n 8.2/1n

From my point of view, a) is correct, but b) is not good.

I would like to be able to extract dV and dt individually.
As [Ramp] is an obligatory keyword, I hoped it would be
safe to do so .... until I saw b).

Thanks for your help,
John

 

-- 
John Fitzpatrick   <John.Fitzpatrick@ln.cit.alcatel.fr>    
Alcatel CIT, 4 rue de Broglie, 22304 Lannion, France
Tel: (+33)96.04.79.33  Fax: (+33)96.04.85.09