Hello all,
A short question regarding interpretation of a model:
In the IBIS 2.1 spec, the ramp rate is defined as
dV 20% to 80% voltage swing
-- = --------------------------------------
dt Time to take to swing the above voltage
When I scan through a random set of IBIS models, I see the
following entries after the [Ramp] keyword of the following
types:
a) dV/dt_r 1.84/0.65n 1.77/0.65n 1.87/0.53n
b) dV/dt_r 4.1/1n 1.6/1n 8.2/1n
From my point of view, a) is correct, but b) is not good.
I would like to be able to extract dV and dt individually.
As [Ramp] is an obligatory keyword, I hoped it would be
safe to do so .... until I saw b).
Thanks for your help,
John
-- John Fitzpatrick <John.Fitzpatrick@ln.cit.alcatel.fr> Alcatel CIT, 4 rue de Broglie, 22304 Lannion, France Tel: (+33)96.04.79.33 Fax: (+33)96.04.85.09Received on Wed May 15 03:14:08 1996