> Tom, the problem is that some semiconductor vendors are starting to only
> make IBIS models available, they don't want to release SPICE models (at
> times they release them under NDA, which is a nuisance for it can take up
> to a month to get all the signatures).
> I use HSPICE for computer system signal integrity analysis and have found
> very good correlation to empirical measurements. I have many device HSPICE
> models which are quite accurate. The few IBIS tools available are
> completely different and incompatible with SPICE files. I therefore want
> to continue using HSPICE, but run into a problem at times if I can only get
> IBIS models.
> Does anyone have any thoughts on this?
I agree 100% !!!
Today I need a SPICE model for an 8-pin part. We either take their IBIS
model or we wait a month for the NDA. But I need the SPICE model!
Received on Fri Oct 24 08:46:21 1997