Shripad:
Because the Off state should be mostly very low leakage
current, I would not use the V-I table. I would
approximate the off state with a large [R Series]
value.
Best Regards,
Bob Ross
Interconnectix/Mentor Graphics
> Date: Mon, 25 May 1998 16:57:08 +0531 (IST)
> From: "A. D. Shirpadaraj" <ads@cadence.com>
> Message-Id: <199805251126.QAA17032@corona.cadence.com>
> To: ibis-users@vhdl.org
> Subject: IBIS 3.0: Series MOSFET under off condition
> Hi Guys,
> How to get V-I Table for Series MOSFET switch under OFF condition.
> Is it just keeping Vds at 0(or less than cutin)volt and measuring Ids?
> It means modelling for only leakage current. Am I right?
> IBIS 3.0 spec doesnot explain off state situation.
> Regards
> Shripad
> Cadence Design Systems (India0 Ltd.,
> NOIDA,
> India
Received on Wed May 27 11:15:37 1998