RE: confusion about c_comp

From: Ingraham, Andrew <Andrew.Ingraham@compaq.com>
Date: Thu Dec 21 2000 - 06:13:45 PST

> > Any simulator that uses the V/T data, must be careful enough to use
> > it correctly!
> > ...
>
> It is actually very difficult to implement it correctly.
 
Yes, I'm sure it is!

> C_comp is included in the V/T data, but it is not included in the
> pullup/pulldown data. This means that to be truly correct, some kind
> of add and remove algorithm is needed,
 
? The pullup/pulldown (I/V) data is DC data. C_comp is irrelevant, it has
no effect on the pullup/pulldown data. Maybe I misunderstood you.

Regards,
Andy

 
Received on Thu Dec 21 06:17:30 2000