Re: LVDS receivers with internal termination

From: Kellee Crisafulli <kellee@hyperlynx.com>
Date: Thu Mar 16 2000 - 16:59:04 PST

Hi Scott,

At 11:48 AM 3/16/00 -0800, Scott McMorrow wrote:
>Anyone have any suggestions on how to use IBIS to
>model LVDS receivers with built in internal 100 ohm
>differential terminators?

The existing IBIS specification allows this with
the series resistor.

There is a bug in the IBIS golden parser that gives an
error message if you do it though.

It is also not supported by all simulators today but is
something I think most are adding.

Kellee

---------------------------------------------------------
Have a great day....
Kellee Crisafulli
HyperLynx, a division of Pads Software Inc.
SI,EMC,X-talk and IBIS tools for the Windows platform
E-mail: <mailto:kellee@hyperlynx.com>
web:   <http://www.hyperlynx.com>
---------------------------------------------------------