RE: min typ & max, explained for good.

From: Al Davis <aldavis@ieee.org>
Date: Thu Mar 23 2000 - 20:51:44 PST

But the only parameters that the simulator applies
temperature to are the transit times [TTgnd] and [TTpower],
which are diodes so will always act like the TTL devices.
Received on Thu Mar 23 21:15:48 2000