RE: Ramp data and rising & falling curves

From: Fred Balistreri <fred@apsimtech.com>
Date: Wed May 23 2001 - 16:02:57 PDT

Your ramp data does not look ok. As Syed pointed out check the .out files.
You may want to check the spice netlist circuit files. If you have the spice
plotting tool run the circuit native in spice and take a look at both the
rising/falling data and i/v data. Your circuit files may not be correct.

Best Regards,

Fred Balistreri

-----Original Message-----
From: Syed Huq [mailto:shuq@cisco.com]
Sent: Wednesday, May 23, 2001 4:36 PM
To: tom_dagostino@mentorg.com; ibis-users@eda.org;
Prabhu.Mohan@actel.com
Cc: shuq@cisco.com
Subject: RE: Ramp data and rising & falling curves

I think your .ibs I/V curves are not correct. If this is an I/O, you may
want to
look at you pdxx.out, puxx.out, ddxx.out, duxx.out before you can say your
I/V
curves are correct..

I doubt it's a s2ibis2 bug..

Syed

> From: "Mohan, Prabhu" <Prabhu.Mohan@actel.com>
> To: "'Dagostino, Tom'" <tom_dagostino@mentorg.com>, ibis-users@eda.org
> Cc: "'Syed Huq'" <shuq@cisco.com>
> Subject: RE: Ramp data and rising & falling curves
> Date: Wed, 23 May 2001 16:18:50 -0700
> MIME-Version: 1.0
>
> Hi
>
> I checked. Looks like I am using s2ibis2_fix. There are some convergence
> warnings but spice automatically sets dcon =2 and then it converges.
>
> I plotted the IV curves, they look fine.
>
> Is it possible that this is a s2ibis2 bug?
>
> Thanks
> Prabhu
>
>
> > -----Original Message-----
> > From: Dagostino, Tom [SMTP:tom_dagostino@mentorg.com]
> > Sent: Wednesday, May 23, 2001 1:39 PM
> > To: 'Paul J. Menchini'; ibis-users@eda.org
> > Subject: RE: Ramp data and rising & falling curves
> >
> > I'd need to see the IV data but I will guess the Current in the pull up
> > and pull down tables was zero.
> >
> > Tom Dagostino
> > Modeling Manager
> > Mentor Graphics Corp.
> > SAE
> > tom_dagostino@mentor.com
> > 503-685-1613
> >
> >
> > -----Original Message-----
> > From: Paul J. Menchini [ <mailto:mench@mench.com>]
> > Sent: Wednesday, May 23, 2001 10:47 AM
> > To: ibis-users@eda.org
> > Subject: Fwd: Ramp data and rising & falling curves
> >
> >
> > Hello Ibis Users,
> >
> > This message is being redelivered as it failed when first sent.
> >
> > Please contact the eda.org support staff at support@eda.org if
> > additional support is required.
> >
> > Paul Menchini
> > Lead System Manager
> >
> > Forwarded message:
> > > Received: from plexus-g.actel.com (plexus-g.actel.com [204.33.72.40])
> > > by server.eda.org (8.12.0.Beta7/8.12.0.Beta7) with ESMTP id
> > f4N05ZwL011475
> > > for <ibis-users@eda.org>; Tue, 22 May 2001 17:05:36 -0700 (PDT)
> > > Received: from sv-gw-02.amer.actel.com (sv-gw-02 [190.9.12.13])
> > > by plexus-g.actel.com (Pro-8.9.3/Pro-8.9.3/Actel_hub) with ESMTP
> > id RAA08717
> > > for <ibis-users@eda.org>; Tue, 22 May 2001 17:04:52 -0700 (PDT)
> > > Received: by sv-gw-02.amer.actel.com with Internet Mail Service
> > (5.5.2653.19)
> > > id <J2KWJB2W>; Tue, 22 May 2001 17:04:57 -0700
> > > Message-ID:
> > <0C3D45928631D5118B2B00805FEA496733D712@sv-msg-01.amer.actel.com>
> > > From: "Mohan, Prabhu" <Prabhu.Mohan@actel.com>
> > > To: "'ibis-users@eda.org'" <ibis-users@eda.org>
> > > Subject: Ramp data and rising & falling curves
> > > Date: Tue, 22 May 2001 17:04:50 -0700
> > > MIME-Version: 1.0
> > > X-Mailer: Internet Mail Service (5.5.2653.19)
> > > Content-Type: text/plain
> >
> > > Hello,
> >
> > > I'm using s2ibis to generate ibis models and I'm new to IBIS.
> > > The ramp data and all the rising & falling curves look like this.
There
> > were
> > > no errors or aborted simulations. All the .out files seem to have all
> > the
> > > datapoints.
> > > The pull-up, pull-down, power & ground clamp curves seem to be fine.
> > > Where am I going wrong?
> >
> > > Thanks
> > > Prabhu
> >
> > > [Ramp]
> > > | variable typ min max
> > > dV/dt_r -2.470e-21/0.000 -3.257e-21/0.000
> > -1.816e-21/0.000
> > > dV/dt_f 2.470e-21/0.000 3.257e-21/0.000
1.816e-21/0.000
> >
> > > R_load = 50.0000
> > > |
> > > [Rising Waveform]
> > > R_fixture = 50.0000
> > > V_fixture = 3.3000
> > > V_fixture_min = 3.0000
> > > V_fixture_max = 3.6000
> > > | time V(typ) V(min) V(max)
> > > |
> > > 0.000S NA NA NA
> > > 0.000S NA NA NA
> > > 0.000S NA NA NA
> > > 0.000S NA NA NA
> > > 0.000S NA NA NA
> > > 0.000S NA NA NA
> > > 0.000S NA NA NA
> >
> > > ...
> >
> > > :-)
> > > Prabhu Mohan
> > > Product Engineer
> > > Actel Corp.
> > > 408.522.4412 - work
> >

 
Received on Wed May 23 17:09:23 2001