RE: Question about IBIS model.


Subject: RE: Question about IBIS model.
From: Jon Powell (jpowell@innoveda.com)
Date: Fri Nov 02 2001 - 08:31:40 PST


If you know the value of the internal pull-up, you can just subtract the
linear thevinen values from the IV curve of the total component.

jon

> -----Original Message-----
> From: owner-ibis-users@eda.org [mailto:owner-ibis-users@eda.org]On
> Behalf Of whiz kid
> Sent: Thursday, November 01, 2001 7:27 PM
> To: ibis_users@eda.org
> Cc: ibis-users@eda.org
> Subject: Question about IBIS model.
>
>
> Hi Folks,
> I have a open drain model with built in pullup
> resistor. I need to create a similar model but with
> out the internal pullup. I would really appreciate if
> any of you can suggest as to how I need to approach
> this.
>
> Thanks in Advance.
> Rahul.
>
> __________________________________________________
> Do You Yahoo!?
> Find a job, post your resume.
> http://careers.yahoo.com
>



This archive was generated by hypermail 2b28 : Fri Nov 02 2001 - 08:52:50 PST