[IBIS-Users] Re: Using s2ibis2 in 1.65V range


Subject: [IBIS-Users] Re: Using s2ibis2 in 1.65V range
From: Angulo, John (john_angulo@mentorg.com)
Date: Tue Dec 10 2002 - 12:02:00 PST


The following is posted on behalf of Hazem Hegazy at QualiM. Please send any private replies to hazem@qualim.com only.

-------------------------------------

Hi,

For a 1.65 supply buffer:

- Pulldown range will be -1.65 to 3.3 V.

- Pullup range from -1.65 to 3.3 also in case of the typical corner.

 

 

Both ranges will be swept with 0.05 V step if you want to get the maximum number of point allowed (Maximum accuracy).

So, I think the 3.25 V in the pull up that you are talking about came from ignoring the last step in the pull up sweep.

 

BR,

Hazem Hegazy, M.Sc.

IBIS Modeling Engineer

QualiM

http://www.qualim.com/

Phone: (+20) 106052154

E-mail: hazem@qualim.com
|------------------------------------------------------------------