Hi, Gus,

Not sure which version of ibischk3 you ran. But problem might be one of
the
bugs in ibischk3 version 3.2.8 which was fixed in version 3.2.9.

>> ERROR - Component 'XXXX': [Series Pin Mapping] Pin2 '17': model type
cannot be Series or Series_switch.

Also, you might want to consider submitting this model to the IBIS Model
Review Committee.
http://www.eigroup.org/ibis/support.htm

Cheers,
Lynne