Hello IBIS gurus,

I've created an IBIS model using a spice netlist from the vendor, and I'm wondering what to do with C_comp. My rising and falling waveforms include the effect of C_comp, but what should I put in the IBIS model? I have a spec sheet that says min C_comp is 2.8pF, max is 10pF. Currently I have 5.0pF for typ, 2.8pF min and 10pF max.

Thanks,

Giovanni

|------------------------------------------------------------------