Hi all ,
I have doubt regarding the ramp down and ramp up functions.
While creating the .s2i i have set the simulation time to be 2.5ns.
The pulse signal thereby generated by s2ibis in rdn.spi is
PULSE(2.5 0 0 2.5e-11 2.5e-11 5e-09 1.01e-08)
.TRAN 2.5e-11 2.5e-09
However if i carry ahead with pulse and transient statement then for the other ramp functions then in the final ibis file i get
Ramp]
| variable typ min max
dV/dt_r 0.61/0.13n 8.892e-21/-0.58n 0.82/89.36p
Now dT must be greater than 0 in a Ramp specification and thereby winibis flags off an error.
So I needed to know how i go about this problem.
Looking forward for your comments.
Thanking you.
warm regards
arnab hazarika
|------------------------------------------------------------------
|For help or to subscribe/unsubscribe, email majordomo@eda.org
|with just the appropriate command message(s) in the body:
|
| help
| subscribe ibis <optional e-mail address, if different>
| subscribe ibis-users <optional e-mail address, if different>
| unsubscribe ibis <optional e-mail address, if different>
| unsubscribe ibis-users <optional e-mail address, if different>
|
|or email a written request to ibis-request@eda.org.
|
|IBIS reflector archives exist under:
|
| http://www.eda.org/pub/ibis/email_archive/ Recent
| http://www.eda.org/pub/ibis/users_archive/ Recent
| http://www.eda.org/pub/ibis/email/ E-mail since 1993
Received on Thu Jan 20 05:47:17 2005
This archive was generated by hypermail 2.1.8 : Thu Jan 20 2005 - 05:49:00 PST