[IBIS-Users] C_comp value

From: lau yy <tok47_at_.....>
Date: Thu May 05 2005 - 18:26:50 PDT
Dear ALL,


I am now generating a IBIS model using ver 2.1.

I face a problem.

In the .s2i file, I have this model
[Model] IO18
[Model type] I/O
.
.
.
[C_comp] 13.328pF 12.868pF 14.168pF

After I generate it, it shows
WARNING - Model 'IO18': C_comp TYP value 1.3328e+13pF out of expected range 
(0pF, 1000pF)
WARNING - Model 'IO18': C_comp MAX value 1.2868e+13pF out of expected range 
(0pF, 1000pF)

How can I solve this problem?


thanks


Rdgs
YYLAU


|------------------------------------------------------------------