Dear ALL, I am now generating a IBIS model using ver 2.1. I face a problem. In the .s2i file, I have this model [Model] IO18 [Model type] I/O . . . [C_comp] 13.328pF 12.868pF 14.168pF After I generate it, it shows WARNING - Model 'IO18': C_comp TYP value 1.3328e+13pF out of expected range (0pF, 1000pF) WARNING - Model 'IO18': C_comp MAX value 1.2868e+13pF out of expected range (0pF, 1000pF) How can I solve this problem? thanks Rdgs YYLAU |------------------------------------------------------------------ |For help or to subscribe/unsubscribe, email majordomo@eda.org |with just the appropriate command message(s) in the body: | | help | subscribe ibis <optional e-mail address, if different> | subscribe ibis-users <optional e-mail address, if different> | unsubscribe ibis <optional e-mail address, if different> | unsubscribe ibis-users <optional e-mail address, if different> | |or email a written request to ibis-request@eda.org. | |IBIS reflector archives exist under: | | http://www.eda.org/pub/ibis/email_archive/ Recent | http://www.eda.org/pub/ibis/users_archive/ Recent | http://www.eda.org/pub/ibis/email/ E-mail since 1993Received on Thu May 5 18:26:54 2005
This archive was generated by hypermail 2.1.8 : Thu May 05 2005 - 18:28:27 PDT