Hi Vinayak, I have noticed below points from the data you pasted herewith 1) what is the significance of generating POWER clamp table for 1.8 to 1.96 ? because this might captured in GND clamp range. 2) if the data started from -1.8 (assuming buffer operating at 1.8V) data is captured till 1.9818V (1.8 + 0.1818182) i.e actual POWER clamp data is present for 1.9818V to 3.6V coming to data present between 1.8V to 1.963636V is actual Vpad of 0V to 0.1636V . usually the voltage value for IV data is as follows Pu/Pd tables --------> -1.8 to 3.6V GND clamp tables ---------> -1.8 to 1.8V POWER clamp tables --------> 1.8V to 3.6V Coming to warning I think data is -1.8 to -0.1818182 follows one order(+vely increasing) after that 1.963636 to 1.8V follows other order (+vely decreasing) Hope this helps you Best Regards Kiran Kumar ________________________________ From: owner-ibis-users@server.eda-stds.org [mailto:owner-ibis-users@server.eda-stds.org] On Behalf Of Vinayak Sent: Monday, August 07, 2006 2:03 PM To: ibis@server.eda-stds.org Cc: ibis-users@server.eda-stds.org Subject: [IBIS-Users] IBIS non-monotonicity issue Hi, I was trying run ibischk4 on the ibis model it gives a warning as WARNING (line 165) - POWER Clamp Voltage data is non-monotonic though i could not find any non-monotonicity in the values in the ibis model. -0.2181818 0.1062643m 46.73129u 0.2034879m -0.2 0.106231m 46.71362u 0.2034473m -0.1818182 0.1061977m 46.69595u 0.2034067m 1.963636 0.106169m 46.68056u 0.2033726m 1.945455 0.1061409m 46.66543u 0.2033392m ----> line 165 1.927273 0.1061128m 46.6503u 0.2033058m 1.909091 0.106087m 46.63619u 0.2032756m 1.890909 0.1060628m 46.62276u 0.2032475m 1.872727 0.1060386m 46.60933u 0.2032194m 1.854545 0.1060153m 46.59625u 0.2031925m 1.836364 0.1059939m 46.58398u 0.2031681m 1.818182 0.1059725m 46.57171u 0.2031437m 1.8 0.1059511m 46.55944u 0.2031194m Should i ignore this warning. Regards vinayak The information contained in this electronic message and any attachments to this message are intended for the exclusive use of the addressee(s) and may contain proprietary, confidential or privileged information. If you are not the intended recipient, you should not disseminate, distribute or copy this e-mail. Please notify the sender immediately and destroy all copies of this message and any attachments. WARNING: Computer viruses can be transmitted via email. The recipient should check this email and any attachments for the presence of viruses. The company accepts no liability for any damage caused by any virus transmitted by this email. www.wipro.com -------------------------------------------------------------------- |For help or to subscribe/unsubscribe, e-mail majordomo@eda-stds.org |with the appropriate command message(s) in the body: | | help | subscribe ibis <optional e-mail address, if different> | subscribe ibis-users <optional e-mail address, if different> | unsubscribe ibis <optional e-mail address, if different> | unsubscribe ibis-users <optional e-mail address, if different> | |or e-mail a request to ibis-request@eda-stds.org. | |IBIS reflector archives exist under: | | http://www.eda-stds.org/pub/ibis/email_archive/ Recent | http://www.eda-stds.org/pub/ibis/users_archive/ Recent | http://www.eda-stds.org/pub/ibis/email/ E-mail since 1993Received on Mon Aug 7 02:56:59 2006
This archive was generated by hypermail 2.1.8 : Mon Aug 07 2006 - 02:58:51 PDT