[IBIS-Users] Clarification in pullup curve

From: Shrikant G Kadadevar - NSBG <Shrikant.G.Kadadevar_at_.....>
Date: Tue Sep 02 2008 - 04:33:42 PDT
Hello All,

Suppose I have the separate VCC for logic level and ESD clamp ie 1.8 and 
3.3.
In this case when calculating the pullup/PGclamp curve, what would be 
the relative voltage I should consider for curve.
That is my pullup curve would be VCC-V_sweep, what should be VCC?

Thanks,
Shrikant



-- 