Hi Nikonchuk:
This is the right group to ask IBIS questions. Here is a quick
responses without commenting on all of the points you raised.
Q1. You are correct that the ranges for I-V table are based
on the typical Vcc rather than the actual Vcc. So the minimum
column can have some overlap and the maximium column can miss
some currents at the ends of the range (if it were extended to
-Vcc_max to 2*Vcc_max).
As a practical matter, EDA tools can and will extend the range
if needed, either by extrapolation or extension of the table.
That should be accurate enough for the unlikely case of having
simulations converge in that region. (It that were the case,
there is probably a design problem or simulation setup problem
that needs to be resolved.) So there was no compelling
reason for use the Vcc_max value as the basis for suggesting
the table ranges.
However, you are allowed to go beyond the ranges suggested
by IBIS as long as they apply for all three columns.
Q2. The specific question is why the ranges -Vcc to Vcc
were chosen for [Gnd Clamp], and Vcc to 2Vcc for [Power Clamp].
In the early days of IBIS (1993), the specification was written
for both CMOS and bi-polar transistors and TTL devices (e.g.,
74F244) where the input had a bias resistor to Vcc through a diode.
So the I-V table showedsmall negative current until the voltage
reached about 2 V (with a 5 V Vcc). Then it cut off to nearly 0 A.
The IBIS authors chose to use the [Gnd Clamp] table extended to Vcc
to capture this effect.
Otherwise, the authors might have split the difference an
had the ranges of the [Gnd Clamp] and [Power Clamp] table
meet in the middle (Vcc/2). But that choice would have
produced a clamp table "gap" at that point of interest
if the ranges had not been chosen to extend to Vcc_max
per Q1.
There are other comments with your other statements, which I will
only summarize. If the non-monotonic issues is in the numerical
"noise" region or as a result of some double counting due to
the extraction tool algorithm, it would be permissible to
correct the data and take out a few points or zero the data
of one of the tables.
If there are on-die terminators, then the correction of the
tables need to be carefully considered based on other information
to avoid double counting - based on what rail or rails the
ODT is referenced. But the main point is that the currents
of both the [Power Clamp] and {Gnd Clamp] add together
for all points in both tables including the extended points
that are not specified in either table.
Q3. Without giving specific names, I know of several vendors
that implement the DEQ-style method and split up the ODT into the
components referenced by each rail so that their models correspond
to the physical device structure. The accuracy issue is depends
on the type of analyis and assumptions. But there are
theoretical issues based on tool setups and capabilities
if power and ground package model elements are used, or if
SSO analysis is done (now and with future features). These
issues relate to the Vcc to Gnd impedance changes that may
cause the model to switch abruptly in a manner that does not
correpond to the physical device operation.
Bob
Nikonchuk Sergey-R6294C wrote:
> Dear IBIS Users Community.
> This is a first time when I send e-mail to the IBIS community.
> So, be patient, please, if I am use wrong e-mail address or asking
> questions which one already clarified in some documentation.
> Just point me on right source.
> My particular questions that I hope to get answers highlighted below as
> "Q1, Q2, Q3"
>
> During detailed evaluation of IBIS characterization flow, especially for
> ODT (On-Die Termination) cells,
> we find some issues in Existing s2ibis3 implementation for Clamp current
> capturing and printing in to IBIS model.
>
> 1. The Voltage range not cover Max condition for
> [Pullup]/[Pulldown]/[GND_clamp]/[POWER_clamp] I-V Curves
> As recommended by IBIS standards and Cookbook , the range for the IV
> curves have to be -Vcc::2*Vcc
> Now, for "Vcc" value the "Typ" value used.
> It mean, if we have Typ Vcc =1.8V +/- 0.1V for Max/Min conditions,
> we have -1.8V::3.6V range for IV curves, which one cover Typ and Min
> recommendation,
> But not enough for Max condition, which one should be -1.9V::3.8V
>
> I suggest to extend the range for IV Curves capturing up to Max [Voltage
> Range] value.
> That's have to be applied for All 4 IV curves - [Pullup]/[Pulldown]/[GND
> clamp]/[POWER clamp]
>
> Q1. Is there any particular reasons, comments - Why IV curves referenced
> to Typ Vref? Is there concern to extend IV ranges up to Max Vref ?
>
>
> 2. The Minimum recommended range for Clamp IV capturing cause
> non-monotonysity issue in Final IBIS models.
> Existing implementation of s2ibis3 Assume the Minimum Voltage ranges
> for Clamp Curves:
> [GND_clamp] -Vcc::Vcc
> [POWER_clamp] Vcc:2*Vcc (Ground referenced)
>
> Below is example:
>
>
> [Voltage Range] 3.3000V 3.0000V 3.6000V
> |
> [GND_clamp]
> |Voltage I(typ) I(min) I(max)
> |
> -3.30 -3.5860A -3.6101A -3.4617A
> -3.23 -3.4782A -3.5024A -3.3533A
> -3.16 -3.3704A -3.3947A -3.2450A
> .....
>
> 3.14 31.9335uA 32.7227uA 40.1997uA
> 3.21 32.7095uA 73.2482uA 41.1226uA
> 3.28 33.5298uA 0.2503mA 42.0514uA
> |
> [POWER_clamp]
> |Voltage I(typ) I(min) I(max)
> |
> -3.28 3.5775A 3.6016A 3.4528A
> -3.24 3.5154A 3.5397A 3.3904A
> -3.20 3.4534A 3.4777A 3.3281A
> .....
>
> -0.08 35.8263uA 26.4944uA 47.5355uA
> -0.04 34.5005uA 25.3183uA 46.9642uA
> 0.00 33.7999uA 24.7033uA 46.4029uA
>
> Looks fine so far?
> Now remind that we have [POWER_clamp] values in IBIS file referenced to
> [Voltage range]
>
> Vtable = Vreference - Voutput
>
> So, if we will re-print the [Power_clamp] table for the Ground-reference
> voltages, we will have something like as following:
>
> [POWER_clamp]
> |Voltage I(typ) I(min) I(max)
> |
> 6.88 3.4528A
> 6.84 3.3904A
> 6.80 3.3281A
>
> ....
> 6.58 3.5775A 2.4528A
> 6.54 3.5154A 2.3904A
> 6.50 3.4534A 2.3281A
>
> ....
>
> 6.28 2.5775A 3.6016A 1.4528A
> 6.24 2.5154A 3.5397A 1.3904A
> 6.20 2.4534A 3.4777A 1.3281A
>
> .....
>
> 3.68 39.8263uA 46.4944uA 47.5355uA
> 3.64 38.5005uA 45.3183uA 46.9642uA
> 3.60 37.7999uA 44.7033uA 46.4029uA
>
> ...........
> 3.38 35.8263uA 36.4944uA ?????????
> 3.34 34.5005uA 35.3183uA ?????????
> 3.30 33.7999uA 34.7033uA ?????????
>
> ........
> 3.08 26.4944uA
> 3.04 25.3183uA
> 3.00 24.7033uA
>
> And when [POWER_clamp] and [GND_clamp] combined together and added to
> [Pullip]/[Pulldown] for simulation,
> We have double counting "Min" clamps between 3.0V and 3.3V
> And we have kind of "Hole" for Max clamp between 3.28V and 3.6V
> Does it looks negligible?
>
> inischk4 say No.
>
> WARNING - Model v330_11_c4: POWER Clamp : Typical value never becomes zero
> WARNING - Model v330_11_c4: POWER Clamp : Minimum value never becomes zero
> WARNING - Model v330_11_c4: POWER Clamp : Maximum value never becomes zero
> WARNING - Combined Pulldown for Model: v330_11_c4 Typical data is
> non-monotonic
> WARNING - Combined Pullup for Model: v330_11_c4 Typical data is
> non-monotonic
> WARNING - Combined Pulldown for Model: v330_11_c4 Minimum data is
> non-monotonic
> WARNING - Combined Pullup for Model: v330_11_c4 Minimum data is
> non-monotonic
> WARNING - Combined Pulldown for Model: v330_11_c4 Maximum data is
> non-monotonic
> WARNING - Combined Pullup for Model: v330_11_c4 Maximum data is
> non-monotonic
>
> That's Especially Important for the ODT models, where Clamp currents is
> quite significant
> And cause issues related to accuracy of models simulation.
>
> What the Solution could be for the issue above?
>
> Proposed Solution to extend Simulation ranges for both [Power_clamp] and
> [GND_clamp] to -Vcc::2*Vcc
> (See IBIS_Cookbook_v4.pdf, Table 5-6)
> In this case we will cover whole range.
> BUT! If we will print All the data "As Is" in to IBIS model, Clamp
> Currents will be Duplicated!
> One of the Option to avoid duplication described in IBIS cookbook -
> Sections 5.1.3.4, 5.1.3.5
> If we just "Clip" the data as described - we have to be take care about
> Extrapolation Errors (Section 5.1.3.9)
> At the end - it would be almost the same as "minimal range" and will NOT
> resolve all ibischk4 warning and simulation concerns.
>
> More reasonable Approach, applicable for ODT models as well described in
> Following Presentation:
> http://www.vhdl.org/pub/ibis/summits/jun03b/muranyi3.pdf
>
> This called as "Clip and Extend"
>
> ? Sweep device from -Vcc to 2*Vcc twice: GND and Vcc relative
> ? Cut clamp curves where they reach zero current going left to right
> ? Extrapolate all clamp curves horizontally to 2*Vcc
>
> Opposite to Cookbook Proposal, this approach Cut clamp current when it's
> going from Positive to Negative value
> And Extend (Extrapolate) this value to end of characterization range.
>
> In a reality, for plain (non-ODT) buffers it mean
> GND_clamp range: -Vcc::0
> POWER_clamp range 0::2*Vcc (Ground referenced)
>
> Q2: Why Cookbook 4.0 Sections 5.1.3.4, 5.1.3.5 recommend to clip the
> date by Differerent ranges?
> GND_clamp range: -Vcc::Vcc
> POWER_clamp range Vcc::2*Vcc (Ground referenced)
> Is there any concerns to use "Clip and Extend" Approach for All Buffer
> types, not ODT only?
> GND_clamp range: -Vcc::0
> POWER_clamp range 0::2*Vcc (Ground referenced)
>
> The Cookbook recommended Clamp ranges seems contradictive with what
> IBISCHK really expected and potentially could confuse simulators.
> Am I miss something here?
>
> At the same time, during investigation of this issue we find Alternative
> (claimed as more accurate for ODT) approach called as DEC:
> http://www.vhdl.org/pub/ibis/summits/sep05/ross2.pdf
>
> This Approach seems more tricky for Implementation with questionable
> added value in term of accuracy.
>
> Q3: Does anybody implement this approach in they models? What is impact
> in terms of simulation accuracy vs. "Clip and extend"?
> Can anybody share particular code to split clamps according to DEC
> algorithms?
>
>
> I will greatly appreciate any feedback and proposals to address issues
> above.
>
>
> Sergey Nikonchuk
> Characterization and View Generation
> TSO / DT / L&M / IO Pad Cell Libraries
> Freescale Semiconductor, Inc.
> www.freescale.com <http://www.freescale.com/>
>
> Contacts:
> Phone +7 (495) 589 1839
> Mobile +7 (916) 993 3467
> Fax +7 (495) 787 0151
> Sergey.Nikonchuk@freescale.com <mailto:Sergey.Nikonchuk@freescale.com>
>
> This e-mail and any attachments have been classified as:
> [x] Public
> [ ] Internal Use Only
> [ ] Confidential Proprietary
>
>
>
>
>
> --
> This message has been scanned for viruses and
> dangerous content by MailScanner <http://www.mailscanner.info/>, and is
> believed to be clean.
-- Bob Ross Teraspeed Consulting Group LLC Teraspeed Labs 121 North River Drive 13610 SW Harness Lane Narragansett, RI 02882 Beaverton, OR 97008 401-284-1827 503-430-1065 http://www.teraspeed.com 503-246-8048 Direct bob@teraspeed.com Teraspeed is a registered service mark of Teraspeed Consulting Group LLC -- This message has been scanned for viruses and dangerous content by MailScanner, and is believed to be clean. -------------------------------------------------------------------- |For help or to subscribe/unsubscribe, e-mail majordomo@eda-stds.org |with the appropriate command message(s) in the body: | | help | subscribe ibis <optional e-mail address, if different> | subscribe ibis-users <optional e-mail address, if different> | unsubscribe ibis <optional e-mail address, if different> | unsubscribe ibis-users <optional e-mail address, if different> | |or e-mail a request to ibis-request@eda-stds.org. | |IBIS reflector archives exist under: | | http://www.eda-stds.org/pub/ibis/email_archive/ Recent | http://www.eda-stds.org/pub/ibis/users_archive/ Recent | http://www.eda-stds.org/pub/ibis/email/ E-mail since 1993Received on Fri Jan 22 14:58:24 2010