To IBIS Committee, Jon, Kellee:
(1) Should the V/I table checks be EQUAL-or-INCREASING and EQUAL-or-
DECREASING? Do ALL simulators which require Monotonic Current support EQUAL
current values within the voltage range?
(2) My understanding is that the error is a "Warning" Error. It serves two
purposes:
(a) Warn the user of a general incorrect Current sign problem
(b) Warn the user of non-monotonic data
(3) If the data is non-monotonic, AND the simulator requires Monotonic data,
(a) The data can be rejected
(b) The user can edit the IBIS file to force monotonic data
(c) The simulator itself could have an automatic monontonic filter (and
issue a warning message if invoked) when reading the IBIS file into
the internal data base.
Received on Wed Mar 16 19:17:42 1994
This archive was generated by hypermail 2.1.8 : Fri Jun 03 2011 - 09:52:28 PDT