Hello Barry --
Thanks for your comment. The reason the C_fixture is between the
R and L is so that one could duplicate the standard 500 ohm, 50pf data
book test load.
Regards,
Stephen Peters
Steve,
Great work!
My only comment is on the figure. I believe the R_fixture and
L_fixture should be in series as is shown below.
Comments?
Barry-
*** Proposed Change ****
|
| |
| |
| PACKAGE | TEST FIXTURE
| _________ |
| | DUT | L_dut R_dut | L_fixture R_fixture
| | die |__@@@@@__/\ /\______|__@@@@_______/\ /\_____ V_fixture
| | | \/ | | \/ |
| |_________| | | |
| | | |
| C_dut === | === C_fixture
| | | |
| | | |
| gnd | gnd
|
*** What you have ****
| |
| |
| PACKAGE | TEST FIXTURE
| _________ |
| | DUT | L_dut R_dut | L_fixture R_fixture
| | die |__@@@@@__/\ /\______|__@@@@_______/\ /\_____ V_fixture
| | | \/ | | | \/
| |_________| | | |
| | | |
| C_dut === | === C_fixture
| | | |
| | | |
| gnd | gnd
|