Since in the case of a non 3-statable buffer this
| difference curve cannot be generated through lab
| measurements (because the clamping curves can not be
| measured alone), the pullup and pulldown curves of
| an IBIS model may contain the sum of the clamping
| characteristics and the output structure. In this
| case the clamping curves must contain all zeroes, or
| the keywords must be omitted.
|
In the above case non-3statable buffer, I will pprefer if the clamping
curves are not present at all, rather than zeroing them.
But either of the choices should not affect the parsing or the final simulation.
- kumar
Received on Wed May 11 07:04:36 1994