Chris and IBIS Committee:
You are right, I can find no reference describing under what conditions
the T-V data is taken. However, a reasonable assumption is that it should
be taken under exactly the same conditions as the [Ramp] data (which also
are the same conditions for the V-I tables). This allows total consistency
of V-I data, T-V data and [Ramp] data for the min and max columns. This
is the most reasonable assumption for processing IBIS data and for automatically
generating IBIS models.
This relates also to an issue I discussed with Stephen Peters regarding whether
C_comp min and max values also should be aligned to the Voltage/Temperature
conditions. This issue has additional complications if the data is not
available from Spice models or measurement.
I think it is reasonable to make such a correction to IBIS. Perhaps a Version 2.2
release for minor typos and some completeness-clarification remarks is in order.
Bob Ross
Interconnectix, Inc.
> Fellow Ibisians,
> It is not clear from the Ibis 2.1 spec whether or not the
> T-V curves (Rising Waveform and Falling Waveform) are supposed
> to be temperature interpolated in the same manner as the V-I
> curves or not.
> I am assuming temperature-interpolation for T-V curves is
> intended. If so the Ibis 2.1 comments should be appended
> to this effect.
> Chris
Received on Tue Jan 17 14:24:10 1995
This archive was generated by hypermail 2.1.8 : Fri Jun 03 2011 - 09:52:28 PDT