Hi All,
As you may recall, here are the original enhancement checks proposed
in EGG 10.
1) Current direction reversed over 50% of points in table.
2) Waveform "DC" points do not match VI curve for specified load.
3) Extreme currents in VI curve. (Generally found shunt curves)
4) Very few transition points in VI curve.
5) Ridiculous values for some parameters.
Comments on 1:
Appears to already be handled sufficiently. No need for change.
Comments on 2:
Involves combining VI curves and interpolation which results in
programming costs and debugging and testing and qa'ing etc....
I have alreadly developed most of the subroutines necc. to
implement this here at Quad into our translator and also have a
good set of files to test it on.
I feel the most efficient way to implement this is for me to do it
here, test it, propose the alogorithm used, and upon acceptance by
the ibis committee, "donate" the code to the ibis forum. Since
this improves overall quality of the ibis models Quad Design has no
objections to this. Drawbacks to this are that I MAY not be
able to tackle this for a few months.
Another way to handle this if there is immediate interest is to
hash out exactly what it needs to do and hand it off to programmers.
Additionally, the test should also check that a driver is able to
drive through the Vref Rref parms specified for the "time to
"measurement" voltage.
Comments on 3:
Shunt Currents Exceeding 10.0Amps @ -1.5 Volts
This appears to be a good voltage to check since the shunt will
be on very strong at 1.5Volts. Interpolation is neccessary to
get this value.
Example message...
WARNING (line 45) - Extreme shunt currents present in GND_Clamp.
Comments on 4:
This one received quite a bit of resistance and would be trickier
and more time consuming to implement properly and handle all cases
(esp raw lab data). I would like to axe this proposed test for
the time being.
* As a side note, it sounds to me that ibis model developers using
raw lab data to generate the VI curves are in need of utility
program that post-processes the data to smooth out any "jitter"
data so it is both monotonic and linearized. By linearized I
mean that there contains JUST ENOUGH points to get the shape
of the curve w/o providing "redundant" points.
The linearization part of the utility could also be applied to
post process simulation data in order to reduce the size of
VI tables within .ibs files w/o a loss of accuracy.
Comments on 5:
From the tables included below, I propose the following values as
top end limits for these parameters. This is easy to implement
and could be handed off to programmers immediately upon
approval.
C_comp 50 pF
Pin C 50 pF
Pin L 50 nH
Pin R 5 Ohms
Ramp Times 10 nSec
Example Message...
WARNING (line 43) - Excessive capacitance value for C_comp.
* The data used to determine these values concludes this mail.
This issue is on the agenda for the meeting tomorrow morning.
Regards,
-Chris Rokusek
Quad Design
DATA used to come up with values for #5:
SHUNT CURRENT at V = -0.50 (GND CLAMP)
PERCENT (of 307) EXCEEDING ->
0 10 20 30 40 50 60 70 80 90 100
I(Amps)|----|----|----|----|----|----|----|----|----|----|
0.0000 |**************************************************
0.0019 |**********
0.0039 |*********
0.0058 |**
0.0078 |*
0.0097 |*
0.0116 |*
0.0136 |*
0.0155 |*
0.0175 |*
0.0194 |*
0.0214 |*
0.0233 |*
0.0252 |*
0.0272 |*
0.0291 |*
0.0311 |*
0.0330 |*
0.0349 |*
0.0369 |*
0.0388 |*
0.0408 |*
0.0427 |*
0.0446 |*
0.0466 |*
0.0485 |*
0.0505 |*
0.0524 |*
0.0544 |*
0.0563 |*
0.0582 |*
0.0602 |*
0.0621 |*
0.0641 |*
0.0660 |*
0.0679 |*
0.0699 |*
0.0718 |*
0.0738 |*
0.0757 |*
SHUNT CURRENT at V = -0.50 (POWER CLAMP)
PERCENT (of 303) EXCEEDING ->
0 10 20 30 40 50 60 70 80 90 100
I(Amps)|----|----|----|----|----|----|----|----|----|----|
0.0000 |**************************************************
0.0259 |*
0.0517 |*
0.0776 |*
0.1034 |*
0.1293 |*
0.1551 |*
0.1810 |*
0.2068 |*
0.2327 |*
0.2586 |*
0.2844 |*
0.3103 |*
0.3361 |*
0.3620 |*
0.3878 |*
0.4137 |*
0.4396 |*
0.4654 |*
0.4913 |*
0.5171 |*
0.5430 |*
0.5688 |*
0.5947 |*
0.6205 |*
0.6464 |*
0.6723 |*
0.6981 |*
0.7240 |*
0.7498 |*
0.7757 |*
0.8015 |*
0.8274 |*
0.8532 |*
0.8791 |*
0.9050 |*
0.9308 |*
0.9567 |*
0.9825 |*
1.0084 |*
SHUNT CURRENT at V = -1.00 (GND CLAMP)
PERCENT (of 307) EXCEEDING ->
0 10 20 30 40 50 60 70 80 90 100
I(Amps)|----|----|----|----|----|----|----|----|----|----|
0.0000 |**************************************************
0.7575 |***
1.5150 |**
2.2725 |**
3.0300 |**
3.7875 |**
4.5450 |*
5.3025 |*
6.0600 |*
6.8175 |*
7.5750 |*
8.3325 |*
9.0900 |*
9.8475 |*
10.6050 |*
11.3625 |*
12.1200 |*
12.8775 |*
13.6350 |*
14.3925 |*
15.1500 |*
15.9075 |*
16.6650 |*
17.4225 |*
18.1800 |*
18.9375 |*
19.6950 |*
20.4525 |*
21.2100 |*
21.9675 |*
22.7250 |*
23.4825 |*
24.2400 |*
24.9975 |*
25.7550 |*
26.5125 |*
27.2700 |*
28.0275 |*
28.7850 |*
29.5425 |*
SHUNT CURRENT at V = -1.00 (POWER CLAMP)
PERCENT (of 303) EXCEEDING ->
0 10 20 30 40 50 60 70 80 90 100
I(Amps)|----|----|----|----|----|----|----|----|----|----|
0.0000 |**************************************************
0.2109 |************
0.4218 |*******
0.6327 |*****
0.8436 |**
1.0544 |*
1.2653 |*
1.4762 |*
1.6871 |*
1.8980 |*
2.1089 |*
2.3198 |*
2.5307 |*
2.7415 |*
2.9524 |*
3.1633 |*
3.3742 |*
3.5851 |*
3.7960 |*
4.0069 |*
4.2178 |*
4.4286 |*
4.6395 |*
4.8504 |*
5.0613 |*
5.2722 |*
5.4831 |*
5.6940 |*
5.9049 |*
6.1158 |*
6.3266 |*
6.5375 |*
6.7484 |*
6.9593 |*
7.1702 |*
7.3811 |*
7.5920 |*
7.8029 |*
8.0137 |*
8.2246 |*
SHUNT CURRENT at V = -1.50 (GND CLAMP)
PERCENT (of 307) EXCEEDING ->
0 10 20 30 40 50 60 70 80 90 100
I(Amps)|----|----|----|----|----|----|----|----|----|----|
0.0000 |**************************************************
0.7575 |*************
1.5150 |********
2.2725 |***
3.0300 |**
3.7875 |**
4.5450 |**
5.3025 |**
6.0600 |**
6.8175 |**
7.5750 |**
8.3325 |**
9.0900 |**
9.8475 |**
10.6050 |**
11.3625 |**
12.1200 |**
12.8775 |**
13.6350 |*
14.3925 |*
15.1500 |*
15.9075 |*
16.6650 |*
17.4225 |*
18.1800 |*
18.9375 |*
19.6950 |*
20.4525 |*
21.2100 |*
21.9675 |*
22.7250 |*
23.4825 |*
24.2400 |*
24.9975 |*
25.7550 |*
26.5125 |*
27.2700 |*
28.0275 |*
28.7850 |*
29.5425 |*
SHUNT CURRENT at V = -1.50 (POWER CLAMP)
PERCENT (of 303) EXCEEDING ->
0 10 20 30 40 50 60 70 80 90 100
I(Amps)|----|----|----|----|----|----|----|----|----|----|
0.0000 |**************************************************
0.7575 |***********
1.5150 |*******
2.2725 |**
3.0300 |*
3.7875 |*
4.5450 |*
5.3025 |*
6.0600 |*
6.8175 |*
7.5750 |*
8.3325 |*
9.0900 |*
9.8475 |*
10.6050 |*
11.3625 |*
12.1200 |*
12.8775 |*
13.6350 |*
14.3925 |*
15.1500 |*
15.9075 |*
16.6650 |*
17.4225 |*
18.1800 |*
18.9375 |*
19.6950 |*
20.4525 |*
21.2100 |*
21.9675 |*
22.7250 |*
23.4825 |*
24.2400 |*
24.9975 |*
25.7550 |*
26.5125 |*
27.2700 |*
28.0275 |*
28.7850 |*
29.5425 |*
SHUNT CURRENT at V = -2.00 (GND CLAMP)
PERCENT (of 307) EXCEEDING ->
0 10 20 30 40 50 60 70 80 90 100
I(Amps)|----|----|----|----|----|----|----|----|----|----|
0.0000 |**************************************************
0.7575 |*********************
1.5150 |***********
2.2725 |********
3.0300 |****
3.7875 |***
4.5450 |**
5.3025 |**
6.0600 |**
6.8175 |**
7.5750 |**
8.3325 |**
9.0900 |**
9.8475 |**
10.6050 |**
11.3625 |**
12.1200 |**
12.8775 |**
13.6350 |**
14.3925 |**
15.1500 |**
15.9075 |**
16.6650 |**
17.4225 |**
18.1800 |**
18.9375 |**
19.6950 |**
20.4525 |**
21.2100 |**
21.9675 |**
22.7250 |*
23.4825 |*
24.2400 |*
24.9975 |*
25.7550 |*
26.5125 |*
27.2700 |*
28.0275 |*
28.7850 |*
29.5425 |*
SHUNT CURRENT at V = -2.00 (POWER CLAMP)
PERCENT (of 303) EXCEEDING ->
0 10 20 30 40 50 60 70 80 90 100
I(Amps)|----|----|----|----|----|----|----|----|----|----|
0.0000 |**************************************************
0.7575 |************
1.5150 |***********
2.2725 |*******
3.0300 |*****
3.7875 |**
4.5450 |*
5.3025 |*
6.0600 |*
6.8175 |*
7.5750 |*
8.3325 |*
9.0900 |*
9.8475 |*
10.6050 |*
11.3625 |*
12.1200 |*
12.8775 |*
13.6350 |*
14.3925 |*
15.1500 |*
15.9075 |*
16.6650 |*
17.4225 |*
18.1800 |*
18.9375 |*
19.6950 |*
20.4525 |*
21.2100 |*
21.9675 |*
22.7250 |*
23.4825 |*
24.2400 |*
24.9975 |*
25.7550 |*
26.5125 |*
27.2700 |*
28.0275 |*
28.7850 |*
29.5425 |*
SHUNT CURRENT at V = -2.50 (GND CLAMP)
PERCENT (of 307) EXCEEDING ->
0 10 20 30 40 50 60 70 80 90 100
I(Amps)|----|----|----|----|----|----|----|----|----|----|
0.0000 |**************************************************
0.7575 |***********************
1.5150 |*************
2.2725 |***********
3.0300 |********
3.7875 |*****
4.5450 |****
5.3025 |***
6.0600 |***
6.8175 |**
7.5750 |**
8.3325 |**
9.0900 |**
9.8475 |**
10.6050 |**
11.3625 |**
12.1200 |**
12.8775 |**
13.6350 |**
14.3925 |**
15.1500 |**
15.9075 |**
16.6650 |**
17.4225 |**
18.1800 |**
18.9375 |**
19.6950 |**
20.4525 |**
21.2100 |**
21.9675 |**
22.7250 |**
23.4825 |**
24.2400 |**
24.9975 |**
25.7550 |**
26.5125 |**
27.2700 |**
28.0275 |**
28.7850 |**
29.5425 |**
SHUNT CURRENT at V = -2.50 (POWER CLAMP)
PERCENT (of 303) EXCEEDING ->
0 10 20 30 40 50 60 70 80 90 100
I(Amps)|----|----|----|----|----|----|----|----|----|----|
0.0000 |**************************************************
0.7575 |************
1.5150 |***********
2.2725 |*******
3.0300 |*******
3.7875 |*******
4.5450 |****
5.3025 |*
6.0600 |*
6.8175 |*
7.5750 |*
8.3325 |*
9.0900 |*
9.8475 |*
10.6050 |*
11.3625 |*
12.1200 |*
12.8775 |*
13.6350 |*
14.3925 |*
15.1500 |*
15.9075 |*
16.6650 |*
17.4225 |*
18.1800 |*
18.9375 |*
19.6950 |*
20.4525 |*
21.2100 |*
21.9675 |*
22.7250 |*
23.4825 |*
24.2400 |*
24.9975 |*
25.7550 |*
26.5125 |*
27.2700 |*
28.0275 |*
28.7850 |*
29.5425 |*
C_comp Values
PERCENT (of 488) EXCEEDING ->
0 10 20 30 40 50 60 70 80 90 100
C(pF)|----|----|----|----|----|----|----|----|----|----|
0.0000 |**************************************************
0.4318 |***********************************************
0.8636 |*****************************
1.2953 |************************
1.7271 |************************
2.1589 |***********************
2.5907 |***********************
3.0224 |*********************
3.4542 |*******************
3.8860 |****************
4.3177 |************
4.7495 |***********
5.1813 |********
5.6131 |********
6.0448 |****
6.4766 |****
6.9084 |****
7.3402 |**
7.7720 |*
8.2037 |*
8.6355 |*
9.0673 |*
9.4991 |*
9.9308 |*
10.3626 |*
10.7944 |*
11.2262 |*
11.6579 |*
12.0897 |*
12.5215 |*
12.9532 |*
13.3850 |*
13.8168 |*
14.2486 |*
14.6804 |*
15.1121 |*
15.5439 |*
15.9757 |*
16.4074 |*
16.8392 |*
PIN C Values
PERCENT (of 1684) EXCEEDING ->
0 10 20 30 40 50 60 70 80 90 100
C(pF)|----|----|----|----|----|----|----|----|----|----|
0.0000 |**************************************************
2.5250 |************
5.0500 |**
7.5750 |*
10.1000 |*
12.6250 |*
15.1500 |*
17.6750 |*
20.2000 |*
22.7250 |*
25.2500 |*
27.7750 |*
30.3000 |*
32.8250 |*
35.3500 |*
37.8750 |*
40.4000 |*
42.9250 |*
45.4500 |*
47.9750 |*
50.5000 |*
53.0250 |*
55.5500 |*
58.0750 |*
60.6000 |*
63.1250 |*
65.6500 |*
68.1750 |*
70.7000 |*
73.2250 |*
75.7500 |*
78.2750 |*
80.8000 |*
83.3250 |*
85.8500 |*
88.3750 |*
90.9000 |*
93.4250 |*
95.9500 |*
98.4750 |*
PIN L Values
PERCENT (of 1684) EXCEEDING ->
0 10 20 30 40 50 60 70 80 90 100
L(nH)|----|----|----|----|----|----|----|----|----|----|
0.0000 |**************************************************
2.5250 |******************************************
5.0500 |***************************
7.5750 |********************
10.1000 |*****************
12.6250 |*******
15.1500 |*
17.6750 |*
20.2000 |*
22.7250 |*
25.2500 |*
27.7750 |*
30.3000 |*
32.8250 |*
35.3500 |*
37.8750 |*
40.4000 |*
42.9250 |*
45.4500 |*
47.9750 |*
50.5000 |*
53.0250 |*
55.5500 |*
58.0750 |*
60.6000 |*
63.1250 |*
65.6500 |*
68.1750 |*
70.7000 |*
73.2250 |*
75.7500 |*
78.2750 |*
80.8000 |*
83.3250 |*
85.8500 |*
88.3750 |*
90.9000 |*
93.4250 |*
95.9500 |*
98.4750 |*
PIN R Values
PERCENT (of 1684) EXCEEDING ->
0 10 20 30 40 50 60 70 80 90 100
R(Ohms)|----|----|----|----|----|----|----|----|----|----|
0.0000 |**************************************************
0.0992 |*************************
0.1985 |*****
0.2977 |****
0.3969 |****
0.4962 |****
0.5954 |****
0.6946 |****
0.7939 |****
0.8931 |**
0.9923 |**
1.0916 |**
1.1908 |**
1.2900 |*
1.3893 |*
1.4885 |*
1.5877 |*
1.6870 |*
1.7862 |*
1.8854 |*
1.9847 |*
2.0839 |*
2.1831 |*
2.2823 |*
2.3816 |*
2.4808 |*
2.5800 |*
2.6793 |*
2.7785 |*
2.8777 |*
2.9770 |*
3.0762 |*
3.1754 |*
3.2747 |*
3.3739 |*
3.4731 |*
3.5724 |*
3.6716 |*
3.7708 |*
3.8701 |*
Ramp Times
PERCENT (of 2184) EXCEEDING ->
0 10 20 30 40 50 60 70 80 90 100
t(ns)|----|----|----|----|----|----|----|----|----|----|
0.0000 |**************************************************
0.1174 |***********************************************
0.2348 |******************************************
0.3522 |*************************************
0.4697 |**********************************
0.5871 |********************************
0.7045 |**************************
0.8219 |******************
0.9393 |*************
1.0567 |**********
1.1741 |*********
1.2915 |******
1.4090 |****
1.5264 |***
1.6438 |**
1.7612 |**
1.8786 |*
1.9960 |*
2.1134 |*
2.2308 |*
2.3483 |*
2.4657 |*
2.5831 |*
2.7005 |*
2.8179 |*
2.9353 |*
3.0527 |*
3.1701 |*
3.2876 |*
3.4050 |*
3.5224 |*
3.6398 |*
3.7572 |*
3.8746 |*
3.9920 |*
4.1094 |*
4.2269 |*
4.3443 |*
4.4617 |*
4.5791 |*
Ramp Volts
PERCENT (of 2184) EXCEEDING ->
0 10 20 30 40 50 60 70 80 90 100
Volts|----|----|----|----|----|----|----|----|----|----|
0.0000 |**************************************************
0.1161 |***********************************************
0.2323 |***********************************************
0.3485 |***********************************************
0.4646 |***********************************************
0.5807 |***********************************************
0.6969 |**********************************************
0.8130 |**********************************************
0.9292 |*********************************************
1.0453 |********************************************
1.1615 |*******************************************
1.2776 |****************************************
1.3938 |************************************
1.5100 |**********************************
1.6261 |*****************************
1.7422 |***************************
1.8584 |***********************
1.9746 |********************
2.0907 |*******************
2.2069 |*****************
2.3230 |***************
2.4392 |*************
2.5553 |*********
2.6714 |********
2.7876 |****
2.9037 |****
3.0199 |***
3.1360 |*
3.2522 |*
3.3684 |*
3.4845 |*
3.6007 |*
3.7168 |*
3.8329 |*
3.9491 |*
4.0652 |*
4.1814 |*
4.2976 |*
4.4137 |*
4.5299 |*
Received on Thu Sep 26 11:15:43 1996