A clamp curve characterizes a clamp diode. This curve should be absolutely
monotonic in forward bias region. In the reverse bias (nano-amp leakage)
region, the curve might not be monotonic. Pullup and pulldown curves are
not always monotonic.
***********************************************************************
* Geoffrey Ellis *
* Cadence Design Systems phone: 831-685-6559 *
* 9057 Soquel Drive fax: 831-685-6556 *
* Aptos, CA 95003 E-mail: geoff@cadence.com *
***********************************************************************
Received on Thu Aug 6 15:56:49 1998