Re: A question for IBIS data

From: Bob Ross <bob_ross@mentorg.com>
Date: Fri Apr 13 2001 - 14:34:31 PDT

Hello Moo-yeul:

The waveform is taken at the junction of the _dut and _fixture
parameters if the _dut parameters exist. Otherwise, it is taken
at the output node directly.

Bob Ross
Mentor Graphics

ÃÖ¹«¿­ wrote:
>
> Hello,
>
> My name is Moo-yeul Choi, the graduate student of Kyungpook National
> University, KOREA.
> I have studied the IBIS to SPICE modeling and have a question about rising and
> falling waveform. I know that the waveform parameter is time-voltage data but
> I don't understand where the voltages are measured. Specially, when the DUT
> parameter exist, I like to know the node measured.
> I am looking foward to your reply, thank you.
> Have a nice day.
>
> Best regards,
> Moo-yeul Choi
 
Received on Fri Apr 13 14:35:22 2001

This archive was generated by hypermail 2.1.8 : Fri Jun 03 2011 - 09:52:30 PDT