Subject: [IBIS] BUG 68 - voltage difference sensitivity
From: Mirmak, Michael (michael.mirmak@intel.com)
Date: Thu May 30 2002 - 17:48:27 PDT
All,
During the last meeting, the IBIS Open Forum suggested that BUG68 should be
considered pending until the sensitivity of the parser in detecting small
voltage differences in I-V curves can be checked (recall that BUG68
identified a problem with parsing I-V curve data where two successive lines
containing the same current points used slightly different voltage points).
By experimenting on the original BUG68 IBIS model using a PC running Windows
2000, I find that the parser must "see" a difference of at least 1e-5 volts
to classify two I-V curve data lines as different. The results were the
same on an HP UNIX system.
An updated version of the IBIS model, with the critical lines highlighted,
is enclosed.
- Michael Mirmak, Intel Corp.
<<bug68a.ZIP>>