RE: [IBIS-Users] RE: [IBIS] Differential Buffer Modelling

From: Kong Yew Chan <KYCHAN_at_.....>
Date: Tue Oct 04 2005 - 03:26:43 PDT
Thanks Arpad! I have further questions, hope you don't mind.

 

1)       Is this method of measuring differential current applicable to
"receiver" with on-die termination?

2)       How does simulators interpret the [Series Current] keyword? Do
they automatically apply the series [Model] upon locating the [Series
Pin Mapping] information when the pins are used? Which simulator
currently supports this keyword? HSPICE? Hyperlynx? 

 

Thanks.

Kong-Yew

 

________________________________

From: owner-ibis-users@eda.org [mailto:owner-ibis-users@eda.org] On
Behalf Of Muranyi, Arpad
Sent: Monday, October 03, 2005 11:49 PM
To: ibis-users@eda.org; ibis@eda.org
Subject: [IBIS-Users] RE: [IBIS] Differential Buffer Modelling

 

Kong-Yew,

 

1)  You are correct.  You would use Idiff and Vdiff for the table

    in [Series Current].

2)  You should use the same response (except with negative polarity)

    for the cancellation that you will use in your final model.  If

    it was an [R Series], use a negative resistance, if it was [Series

    Current], use the same PWL table (with the signs reversed).

 

I hope this helps.

 

Arpad Muranyi

Intel Corporation

=======================================================================

 

________________________________

From: owner-ibis@eda.org [mailto:owner-ibis@eda.org] On Behalf Of Kong
Yew Chan
Sent: Monday, October 03, 2005 6:21 AM
To: ibis-users@eda.org; ibis@eda.org
Subject: [IBIS] Differential Buffer Modelling

IBIS Gurus,

 

I have some questions about generating differential buffer model as
stated in latest Cookbook 4.0.

1)          My normalized differential mode current has a similar plot
as shown in Pg 36. It's a function of the differential voltage, so that
makes the usage of keyword [Series Current] appropriate in this case. To
fill the I-V table, am I supposed to use the Vdiff vs Idiff ?

2)          For the V-T table data extraction, it was mentioned in Pg 40
that for [Series Current] keyword, PWL current source can be used to
replace the R value. What should be the PWL response to represent the
Idiff? (Idiff was only found to be a function of Vdiff from I-V
extraction). 

 

Please advise if my assumptions are incorrect.  

 

Thanks

Kong-Yew



-----------------------------------------------------------------
|For help or to subscribe/unsubscribe, email majordomo@eda.org
|with the appropriate command message(s) in the body:
|
|  help
|  subscribe   ibis       <optional e-mail address, if different>
|  subscribe   ibis-users <optional e-mail address, if different>
|  unsubscribe ibis       <optional e-mail address, if different>
|  unsubscribe ibis-users <optional e-mail address, if different>
|
|or email a request to ibis-request@eda.org.
|
|IBIS reflector archives exist under:
|
|  http://www.eda.org/pub/ibis/email_archive/  Recent
|  http://www.eda.org/pub/ibis/users_archive/  Recent
|  http://www.eda.org/pub/ibis/email/          E-mail since 1993
Received on Tue Oct 4 03:27:13 2005

This archive was generated by hypermail 2.1.8 : Tue Oct 04 2005 - 03:31:14 PDT