Hi All, When creating IBIS EBD model for multi die package, is multiple fork and endfork statement allowed for one main branch? For example if the device has 4 die and from each pad bondwires are connected to one external ball is it okay to describe the path description as below? Note the last fork-endfork statement. Is it necessary that the original path needs to be continued and therefore the path description has to end with a series path? [Path Description] QUAD_DIE_SIGNAL A1 Len=0 R=16.646m L=1.406n C=0.456p / |Substrate R, L and C Fork Len=0 R=10m L=1nH C=1p / |Bondwire r,l,c from pin A1 to U1, pad #21 Endfork Node U1.21 Fork Len=0 R=10m L=1nH C=1p / |Bondwire r,l,c from pin A1 to U2, pad #21 Endfork Node U2.21 Fork |Bondwire r,l,c from pin A1 to U3, pad #21 Len=0 R=10m L=1nH C=1p Endfork Node U3.21 Fork |Bondwire r,l,c from pin A1 to U4 , pad #21 Len=0 R=10m L=1nH C=1p Endfork Node U4.21 Best Regards Moshiul Haque Micron Technology Inc. ----------------------------------------------------------------- |For help or to subscribe/unsubscribe, email majordomo@eda.org |with the appropriate command message(s) in the body: | | help | subscribe ibis <optional e-mail address, if different> | subscribe ibis-users <optional e-mail address, if different> | unsubscribe ibis <optional e-mail address, if different> | unsubscribe ibis-users <optional e-mail address, if different> | |or email a request to ibis-request@eda.org. | |IBIS reflector archives exist under: | | http://www.eda.org/pub/ibis/email_archive/ Recent | http://www.eda.org/pub/ibis/users_archive/ Recent | http://www.eda.org/pub/ibis/email/ E-mail since 1993Received on Fri Dec 30 13:33:21 2005