Hello Ibis experts,
I'm working in CMOS tecnology;
very often in the C_comp extraction I obtain the Min value bigger then Max value:
the values come from ac simulations in these conditions:
C_comp Min value consider: Vcc Min, Process Min, Temp Max
C_comp Max value consider: Vcc Max, Process Max, Temp Min
The Ibis Check output is:
WARNING (line 76) -
Model mod1: C_comp min value is not the smallest value listed
WARNING (line 76) -
Model mod1: C_comp max value is not the largest value listed
Is that situation acceptable?
or I have to switch the Min Value with Max Value?
... suggestions are welcome !
Thank you,
Fabio
-- This message has been scanned for viruses and dangerous content by MailScanner, and is believed to be clean. -------------------------------------------------------------------- |For help or to subscribe/unsubscribe, e-mail majordomo@eda-stds.org |with the appropriate command message(s) in the body: | | help | subscribe ibis <optional e-mail address, if different> | subscribe ibis-users <optional e-mail address, if different> | unsubscribe ibis <optional e-mail address, if different> | unsubscribe ibis-users <optional e-mail address, if different> | |or e-mail a request to ibis-request@eda-stds.org. | |IBIS reflector archives exist under: | | http://www.eda-stds.org/pub/ibis/email_archive/ Recent | http://www.eda-stds.org/pub/ibis/users_archive/ Recent | http://www.eda-stds.org/pub/ibis/email/ E-mail since 1993Received on Mon Sep 27 05:13:18 2010