Hi IBIS experts,
I was modeling some termination (switchable : off/on) as submodel and I ran the this model into hspice QC to check how this behaves.
What I capture as part of submodel are weak pullup ON + diode IV as pwr/gnd clamp and base model where I call this also has diode IV in pwr/.gnd clamps.
When I run QC I find that the currents are double counted.
My interpretation was that the submodel pwr/gnd clamp should replace the base model pwr/gnd clamp tables in Receive mode which I expected to.
This looks not to be the case. Is my understanding wrong. Does submodel gets added to base model?
Is there any way tools can switch to submodel currents only and not add to base model IV ?
Thanks
Vinayak
-- This message has been scanned for viruses and dangerous content by MailScanner, and is believed to be clean. -------------------------------------------------------------------- |For help or to subscribe/unsubscribe, e-mail mikelabonte@eda-stds.org |or ibis-request@eda-stds.org | |IBIS reflector archives exist under: | | http://www.eda-stds.org/ibis/email_archive/ Recent | http://www.eda-stds.org/ibis/users_archive/ Recent | http://www.eda-stds.org/ibis/email/ E-mail since 1993Received on Thu Aug 16 02:13:30 2012