Hi Peter,

I had the same situation a few months ago and I only had to go with an
adhoc solution.

Yes indeed most simulators do not have good support for differential
models with [R Series] termination. I ended up creating a single-ended
input buffer model (same for the P and N side) with no termination
between P and N sides. This only captured the clamping function.

In my simulation I had to recreate the terminated differential input
buffer by using two single-ended buffers (one for the P and one for the
N pin) with a termination resistor tied between them. The package
parasitics were also tied to the two pins. I manually changed the values
of the termination resistor and package parasitics to cover their
variation in the typical, minimum and maximum corners.

Probably there is a better solution, but that's what I did as a
quick-and-dirty work-around.

Regards.

Hassan.

Hassan Ali, Ph.D.
Signal Integrity Specialist -Talented, innovative designers
Fidus Systems Inc. -Highly competitive rates
Tel: (613) 828-0063 Ext.342 -Fixed-price business model
Fax: (613) 828-3113 -State-of-the-art design tools
http://www.fidus.ca -Customer-friendly attitude

-----Original Message-----
From: Peter LaFlamme [mailto:plaflamm@amcc.com]
Sent: Tuesday, July 23, 2002 9:01 AM
To: ibis-users@eda.org
Subject: [IBIS-Users] LVDS RECEIVER TERMINATION Question

Hi All,
I am tasked with creating an IBIS model for an LVDS receiver cell that
has an internal 100 ohm termination between the P and N nodes. I had
asked Bob Ross about this a while ago and as usual he was very helpful.
From his response I used the following
implementation:

|****************************************************************
| Component: LVDSRCV
|****************************************************************
|
[Component] LVDSRCV
[Manufacturer] AMCC
|
|
|
[Package]
| variable typ min max
R_pkg 1E-3 NA NA
L_pkg 1E-9 NA NA
C_pkg 1E-12 NA NA
|
[Pin] signal_name model_name R_pin L_pin C_pin
  1 PAD lvdsrcv NA NA NA
  2 PADN lvdsrcv NA NA NA
|
[Series Pin Mapping] pin_2 model_name function_table_group
1 2 rterm_100

|
[Diff_pin] inv_pin vdiff tdelay_typ tdelay_min
tdelay_max
|
   1 2 0.2 0 0 0

[Model] rterm_100
C_comp 0.1pF 0.1pF 0.1pF

Model_type Series
|variable R(typ) R(min) R(max)
[R Series] 100 80 120

[Temperature Range] 25.00 125.00 0.00
[Voltage Range] 1.800 1.650 1.950

************************************************************************
****************

I was able to get the model past the IBIS checker but my simulations did
not show the 100 ohm terminator. I was using a tool which I believe does
not support this implementation (no need to mention names). I have seen
other implementations where I believe

a "Dynamic clamp" is used to model the termination behavior, but I am
unsure. Can anyone guide me to some reference material or weigh in with
your experience or help.

Thanks alot,
Peter

 

-- 
Peter LaFlamme

Applied Micro Circuits Corp. System Applications Engineer 200 Minuteman Rd, 3rd Floor Andover, MA 01810

978-247-8470 phone 978-623-0055 Fax |------------------------------------------------------------------ |For help or to subscribe/unsubscribe, email majordomo@eda.org |with just the appropriate command message(s) in the body: | | help | subscribe ibis <optional e-mail address, if different> | subscribe ibis-users <optional e-mail address, if different> | unsubscribe ibis <optional e-mail address, if different> | unsubscribe ibis-users <optional e-mail address, if different> | |or email a written request to ibis-request@eda.org. | |IBIS reflector archives exist under: | | http://www.eda.org/pub/ibis/email_archive/ Recent | http://www.eda.org/pub/ibis/users_archive/ Recent | http://www.eda.org/pub/ibis/email/ E-mail since 1993 |------------------------------------------------------------------ |For help or to subscribe/unsubscribe, email majordomo@eda.org |with just the appropriate command message(s) in the body: | | help | subscribe ibis <optional e-mail address, if different> | subscribe ibis-users <optional e-mail address, if different> | unsubscribe ibis <optional e-mail address, if different> | unsubscribe ibis-users <optional e-mail address, if different> | |or email a written request to ibis-request@eda.org. | |IBIS reflector archives exist under: | | http://www.eda.org/pub/ibis/email_archive/ Recent | http://www.eda.org/pub/ibis/users_archive/ Recent | http://www.eda.org/pub/ibis/email/ E-mail since 1993



This archive was generated by hypermail 2b28 : Tue Jul 23 2002 - 09:47:57 PDT