Hi,
Could please clarify the question? The common mode voltage is very
important for the model generation and which method to use. While the Vod is
a model parameter and you can even put it in the model after finishing all
current/wave form tables.
Hazem Hegazy
-----Original Message-----
From: Shee Kian Wong [mailto:SKWONG@altera.com]
Sent: Wednesday, August 28, 2002 10:40 AM
To: ibis-users@server.eda.org
Subject: [IBIS-Users] LVDS modeling method
Hi all,
I've seen a lot of LVDS modeling methods only take care of vos (output
offset voltage) or vcm (common mode voltage).
But how come very seldom people make use of vod (output differential
voltage)? Isn't as important as other parameters?
Please advice.
BM__MailAutoSigBest Regards,