Hi,
This problem occur mainly due to sim time. Try changing the sim time.
regards,
Kapil
-----Original Message-----
From: owner-ibis-users@eda.org [mailto:owner-ibis-users@eda.org] On Behalf Of youngs.hong@samsung.com
Sent: Wednesday, June 23, 2004 1:09 PM
To: ibis-users@eda.org
Subject: [IBIS-Users] End point problem
Hi, experts!
I have been created IBIS model using s2ibis2.
The following messages are created from IBISCHK4.
Please let me know, 1) why these errors occur and 2) What is the solution of this error?
ERROR ? Model RNB : The [falling Waveform]
with [R_fixture]=70 Ohms and [V_fixture]=3.3V
has TYP column DC endpoints of 4.10V and 3.30V, but
and equivalent load applied to the model’s I-V tables yields
different voltages (0.10V and 0.19),
a different of 4187.12% and 3251.19%, respectively.
ERROR ? Model IO : The [Rising Waveform]
with [R_fixture]=70 Ohms and [V_fixture]=3.3V
has TYP column DC endpoints of 0.73V and ?0.73V, but
and equivalent load applied to the model’s I-V tables yields
different voltages (0.73V and 3.30),
a different of 0.02% and 3.30%, respectively.
Regards
Y.S. HONGz??문z뼟쉒혦땋┻쉡굉꿾뻨뎝쬆셢z}}엖뎝괍쥇빆?z옼m듁jju쾤z떴츎볏뒘둽쾳?j쨉z쾳춟u?J븹rz뒡?접쫱?r{q?접쫱r{q?접쫱?솾{
|------------------------------------------------------------------
|For help or to subscribe/unsubscribe, email majordomo@eda.org
|with just the appropriate command message(s) in the body:
|
| help
| subscribe ibis <optional e-mail address, if different>
| subscribe ibis-users <optional e-mail address, if different>
| unsubscribe ibis <optional e-mail address, if different>
| unsubscribe ibis-users <optional e-mail address, if different>
|
|or email a written request to ibis-request@eda.org.
|
|IBIS reflector archives exist under:
|
| http://www.eda.org/pub/ibis/email_archive/ Recent
| http://www.eda.org/pub/ibis/users_archive/ Recent
| http://www.eda.org/pub/ibis/email/ E-mail since 1993
Received on Wed Jun 23 00:49:27 2004
This archive was generated by hypermail 2.1.8 : Wed Jun 23 2004 - 00:49:44 PDT