Hello Tom,

My cell is a differential cell and i make sure there is good current in
IV table. I also find out that my IBIS results perfectly match with my
spice result.

Regards
Akhilesh

Tom Dagostino wrote:

>This model looks like there is zero current in your IV table. Was the
>buffer in a tristate or input mode when the IV sweeps were simulated? Or is
>this an open sink buffer with the load resistor terminated to ground?
>
>Tom Dagostino
>Teraspeed Consulting Group LLC
>503-430-1065
>tom@teraspeed.com
>www.teraspeed.com
>
>-----Original Message-----
>From: owner-ibis-users@eda.org [mailto:owner-ibis-users@eda.org]On
>Behalf Of lgreen
>Sent: Friday, November 05, 2004 8:12 AM
>To: 'Akhilesh CHANDRA'; ibis-users@eda.org; ibis@eda.org
>Subject: RE: [IBIS-Users] warning with ibischk3.2
>
>
>Hello, Akhilesh,
>
>Do both the rising and falling SPICE waveforms pass through 1V with this
>load? If this is a differential buffer, remember that IBIS only checks one
>I/O pad at a time.
>
>I would recommend trying ibishck4 to see if the problem still occurs. You
>could also submit your model to the IBIS model review committee (please
>include "IBIS Model Review Committee" in the subject).
>
>- Lynne
>
>PS: Does your production group really use 1-Meg as their timing test load?
>Many companies use loads around 50-150 Ohms.
>
>
>
>"IBIS training when you need it, where you need it."
>
>Dr. Lynne Green
>Green Streak Programs
>http://www.greenstreakprograms.com
>lgreen22@mindspring.com
>
>
>-----Original Message-----
>From: owner-ibis-users@eda.org [mailto:owner-ibis-users@eda.org] On Behalf
>Of Akhilesh CHANDRA
>Sent: Friday, November 05, 2004 5:16 AM
>To: ibis-users@eda.org; ibis@eda.org
>Cc: Akhilesh CHANDRA
>Subject: [IBIS-Users] warning with ibischk3.2
>
>Hello,
>
> I am geting following warning in one of my differential cell when I
>run ibischk3.2. Can anybody help me to find out how it come and where it
>effect because I run my cell lebel simulation with this model and result
>are near to spice.
>
>WARNING - Model 'LVPECLDRV_3V3': TYP VI curves cannot drive through Vmeas=1V
> given load Rref=1e+06 Ohms to Vref=0.9V
>WARNING - Model 'LVPECLDRV_3V3': MIN VI curves cannot drive through Vmeas=1V
> given load Rref=1e+06 Ohms to Vref=0.9V
>WARNING - Model 'LVPECLDRV_3V3': MAX VI curves cannot drive through Vmeas=1V
> given load Rref=1e+06 Ohms to Vref=0.9Vak, Michael wrote:
>
>
>
>>Regards
>>
>>
>>
>Akhilesh
>
>
>
>>
>>
>
>
>|------------------------------------------------------------------
>|For help or to subscribe/unsubscribe, email majordomo@eda.org
>|with just the appropriate command message(s) in the body:
>|
>| help
>| subscribe ibis <optional e-mail address, if different>
>| subscribe ibis-users <optional e-mail address, if different>
>| unsubscribe ibis <optional e-mail address, if different>
>| unsubscribe ibis-users <optional e-mail address, if different>
>|
>|or email a written request to ibis-request@eda.org.
>|
>|IBIS reflector archives exist under:
>|
>| http://www.eda.org/pub/ibis/email_archive/ Recent
>| http://www.eda.org/pub/ibis/users_archive/ Recent
>| http://www.eda.org/pub/ibis/email/ E-mail since 1993
>
>
>|------------------------------------------------------------------
>|For help or to subscribe/unsubscribe, email majordomo@eda.org
>|with just the appropriate command message(s) in the body:
>|
>| help
>| subscribe ibis <optional e-mail address, if different>
>| subscribe ibis-users <optional e-mail address, if different>
>| unsubscribe ibis <optional e-mail address, if different>
>| unsubscribe ibis-users <optional e-mail address, if different>
>|
>|or email a written request to ibis-request@eda.org.
>|
>|IBIS reflector archives exist under:
>|
>| http://www.eda.org/pub/ibis/email_archive/ Recent
>| http://www.eda.org/pub/ibis/users_archive/ Recent
>| http://www.eda.org/pub/ibis/email/ E-mail since 1993
>
>
>|------------------------------------------------------------------
>|For help or to subscribe/unsubscribe, email majordomo@eda.org
>|with just the appropriate command message(s) in the body:
>|
>| help
>| subscribe ibis <optional e-mail address, if different>
>| subscribe ibis-users <optional e-mail address, if different>
>| unsubscribe ibis <optional e-mail address, if different>
>| unsubscribe ibis-users <optional e-mail address, if different>
>|
>|or email a written request to ibis-request@eda.org.
>|
>|IBIS reflector archives exist under:
>|
>| http://www.eda.org/pub/ibis/email_archive/ Recent
>| http://www.eda.org/pub/ibis/users_archive/ Recent
>| http://www.eda.org/pub/ibis/email/ E-mail since 1993
>
>

|------------------------------------------------------------------
|For help or to subscribe/unsubscribe, email majordomo@eda.org
|with just the appropriate command message(s) in the body:
|
| help
| subscribe ibis <optional e-mail address, if different>
| subscribe ibis-users <optional e-mail address, if different>
| unsubscribe ibis <optional e-mail address, if different>
| unsubscribe ibis-users <optional e-mail address, if different>
|
|or email a written request to ibis-request@eda.org.
|
|IBIS reflector archives exist under:
|
| http://www.eda.org/pub/ibis/email_archive/ Recent
| http://www.eda.org/pub/ibis/users_archive/ Recent
| http://www.eda.org/pub/ibis/email/ E-mail since 1993
Received on Tue Nov 9 01:03:23 2004

This archive was generated by hypermail 2.1.8 : Tue Nov 09 2004 - 01:05:32 PST