Hello Shulong:
In IBIS Version 4.1, there is no direct method to connect the
die pads to pins listed below. As you discovered, there is no
reference through [Circuit Call]s for such a connection. So at
this time the EDA tool would have to provide the connection outside
of the IBIS syntax.
However, solutions are being discussed and should lead to a
proposal for IBIS Version 4.2. The proposals will probably involve
some linkage syntax involving IBIS and the Interconnect Model Specification
(ICM) for a more general package model.
Regards,
Bob
slwu wrote:
> Hi,
>
> I am still not very clear...so giving an exact example may be more
> understood for me.
> In the diagram on Page 112 of the IBIS 4.1 specification, there are several
>
> connections between die pads and pins that I can not understand how they
> are constructed through [Circuit Call]s on Page 113~114
> 1. "pad_11" <====> "11"
> 2. "pad_2a"/"pad_2b" <====> "2"
> 3. "pad_4" <===> "4a" /"4b"
>
> Thanks very much
> slwu
>
-- Bob Ross Teraspeed Consulting Group LLC Teraspeed Labs 121 North River Drive 13610 SW Harness Lane Narragansett, RI 02882 Beaverton, OR 97008 503-750-6481 503-430-1065 http://www.teraspeed.com 503-246-8048 Direct bob@teraspeed.com |------------------------------------------------------------------ |For help or to subscribe/unsubscribe, email majordomo@eda.org |with just the appropriate command message(s) in the body: | | help | subscribe ibis <optional e-mail address, if different> | subscribe ibis-users <optional e-mail address, if different> | unsubscribe ibis <optional e-mail address, if different> | unsubscribe ibis-users <optional e-mail address, if different> | |or email a written request to ibis-request@eda.org. | |IBIS reflector archives exist under: | | http://www.eda.org/pub/ibis/email_archive/ Recent | http://www.eda.org/pub/ibis/users_archive/ Recent | http://www.eda.org/pub/ibis/email/ E-mail since 1993Received on Wed Nov 10 15:36:15 2004
This archive was generated by hypermail 2.1.8 : Wed Nov 10 2004 - 15:37:43 PST