Dear IBIS users, Appreciate your help on clarifying the C_comp parameter in the .s2i file. When I run the s2ibis3, I used an RC extracted netlist as my spectre input. My question is, do I still need to specify the C_comp in the .s2i file, since the RC extraction should have taken care of this capacitance already? Am I double calculating the die capacitance if I include C_comp in .s2i file? How will the default 5pF in the .ibs affect my output if I did not specify any C_comp in .s2i earlier? Appreciate your kind feedback. Thank you. Best regards, Mei Yee -------------------------------------------------------------------- |For help or to subscribe/unsubscribe, e-mail majordomo@eda-stds.org |with the appropriate command message(s) in the body: | | help | subscribe ibis <optional e-mail address, if different> | subscribe ibis-users <optional e-mail address, if different> | unsubscribe ibis <optional e-mail address, if different> | unsubscribe ibis-users <optional e-mail address, if different> | |or e-mail a request to ibis-request@eda-stds.org. | |IBIS reflector archives exist under: | | http://www.eda-stds.org/pub/ibis/email_archive/ Recent | http://www.eda-stds.org/pub/ibis/users_archive/ Recent | http://www.eda-stds.org/pub/ibis/email/ E-mail since 1993Received on Thu Oct 26 17:42:21 2006