[IBIS-Users] RE: [IBIS] IBIS for pad with ESD Clamps

From: Muranyi, Arpad <Arpad_Muranyi_at_.....>
Date: Wed May 21 2008 - 10:44:29 PDT
You could consider using the
"Terminator" model type.
 
Arpad
=============================

________________________________

From: owner-ibis@server.eda.org [mailto:owner-ibis@server.eda.org] On Behalf Of Ajay Kapoor
Sent: Wednesday, May 21, 2008 12:48 AM
To: ibis@server.eda.org; ibis-users@server.eda.org
Subject: [IBIS] IBIS for pad with ESD Clamps


Dear Experts,
 
I have a question regarding IBIS models.
We have an IP that is just a short with only ESD diodes connected between supply rails. 
There is no input or output section in this IP.
Would it be possible to generate IBIS models for such an IP ?
If yes how should it be done ?
 
Thanks
Ajay


-- 
This message has been scanned for viruses and 
dangerous content by MailScanner <http://www.mailscanner.info/> , and is 
believed to be clean. 

-- 
This message has been scanned for viruses and
dangerous content by MailScanner, and is
believed to be clean.


--------------------------------------------------------------------
|For help or to subscribe/unsubscribe, e-mail majordomo@eda-stds.org
|with the appropriate command message(s) in the body:
|
|  help
|  subscribe   ibis       <optional e-mail address, if different>
|  subscribe   ibis-users <optional e-mail address, if different>
|  unsubscribe ibis       <optional e-mail address, if different>
|  unsubscribe ibis-users <optional e-mail address, if different>
|
|or e-mail a request to ibis-request@eda-stds.org.
|
|IBIS reflector archives exist under:
|
|  http://www.eda-stds.org/pub/ibis/email_archive/ Recent
|  http://www.eda-stds.org/pub/ibis/users_archive/ Recent
|  http://www.eda-stds.org/pub/ibis/email/         E-mail since 1993
Received on Wed May 21 10:45:38 2008

This archive was generated by hypermail 2.1.8 : Wed May 21 2008 - 10:47:29 PDT