Hi Tom and Experts, I had attached the ibis files in a *.tar.gz file. I am reattaching the same tar.gz file which contains all the ibis files. I looked at my spice files to see if they differed in signal settings for IV/VT extraction (after Tom's suggestion). They don't differ. My concern is why the warnings show up in the all corner ibis file (all.ibs) when it doesn't show up in the single corner file (ss*.ibs) when in fact the data looks identical (at least for the Pulldown case). Thanks once again Anand ________________________________ From: Tom Dagostino [mailto:tom@teraspeed.com] Sent: Thursday, December 18, 2008 5:44 PM To: Anand Ramalingam; ibis-users@eda.org Subject: RE: [IBIS-Users] IV/VT mismatch warnings with all corners file; no warnings with a single corner file Anand From the data presented (the IBIS files do not come through as attachments) you seem to have a weak pullup (0.4 mA) in the model that is present in the IV curves but was not present when the VT curves were extracted. Re-extract the VTs with the pullup. Tom Dagostino Teraspeed(R) Labs 13610 SW Harness Lane Beaverton, OR 97008 503-430-1065 503-430-1285 FAX tom@teraspeed.com www.teraspeed.com Teraspeed Consulting Group LLC 121 North River Drive Narragansett, RI 02882 401-284-1827 From: owner-ibis-users@server.eda.org [mailto:owner-ibis-users@server.eda.org] On Behalf Of Anand Ramalingam Sent: Thursday, December 18, 2008 3:14 PM To: ibis-users@server.eda.org Subject: [IBIS-Users] IV/VT mismatch warnings with all corners filie; no warnings with a single corner file Hi IBIS Experts, I am trying to figure out why ibischk gives warnings about IV/VT mismtach when I have all the corners in the IBIS file while it passes without any errors or warnings for a single corner file. I am attaching the 3 single corner files (ff_1p32_1p95_m40c.ibs; ss_1p08_1p65_125c.ibs; tt_1p10_1p80_25c.ibs) and one all corner file (all.ibs). When I run a ibischk on all.ibs, I get the following: *------------------------------------------------------ IBISCHK4 V4.1.1 Checking all.ibs for IBIS 4.1 Compatibility... --- first 5 warnings (not related to iv/vt mismatch) deleted --- WARNING - Model MPADN: The [Rising Waveform] with [R_fixture]=50 Ohms and [V_fixture_min]=0V has MIN column DC endpoints of 0.00V and 0.32v, but an equivalent load applied to the model's I-V tables yields different voltages ( 0.02V and 0.34V), a difference of 6.05% and 6.95%, respectively. WARNING - Model MPADN: The [Falling Waveform] with [R_fixture]=50 Ohms and [V_fixture_min]=0V has MIN column DC endpoints of 0.00V and 0.32v, but an equivalent load applied to the model's I-V tables yields different voltages ( 0.02V and 0.34V), a difference of 6.05% and 6.95%, respectively. WARNING - Model MPADP: The [Rising Waveform] with [R_fixture]=50 Ohms and [V_fixture_min]=0V has MIN column DC endpoints of 0.00V and 0.32v, but an equivalent load applied to the model's I-V tables yields different voltages ( 0.02V and 0.34V), a difference of 6.05% and 6.95%, respectively. WARNING - Model MPADP: The [Falling Waveform] with [R_fixture]=50 Ohms and [V_fixture_min]=0V has MIN column DC endpoints of 0.00V and 0.32v, but an equivalent load applied to the model's I-V tables yields different voltages ( 0.02V and 0.34V), a difference of 6.05% and 6.95%, respectively. Errors : 0 Warnings: 9 *------------------------------------------------------------------ I did check manually the Pulldown/Clamp data in single corner file (ss_1p08_1p65_125c.ibs) and the one in min corner of all corner (all.ibs) file. They look identical. I am little puzzled by why there warnings in all.ibs file while none shows up in ss_1p08_1p65_125c.ibs file. I would be glad if someone can help me understand why this warnings show up! Thanks Anand -- This message has been scanned for viruses and dangerous content by MailScanner <http://www.mailscanner.info/> , and is believed to be clean. -- IMPORTANT NOTICE: The contents of this email and any attachments are confidential and may also be privileged. If you are not the intended recipient, please notify the sender immediately and do not disclose the contents to any other person, use it for any purpose, or store or copy the information in any medium. Thank you. -- This message has been scanned for viruses and dangerous content by MailScanner <http://www.mailscanner.info/> , and is believed to be clean. -- This message has been scanned for viruses and dangerous content by MailScanner <http://www.mailscanner.info/> , and is believed to be clean. -- This message has been scanned for viruses and dangerous content by MailScanner, and is believed to be clean. -------------------------------------------------------------------- |For help or to subscribe/unsubscribe, e-mail majordomo@eda-stds.org |with the appropriate command message(s) in the body: | | help | subscribe ibis <optional e-mail address, if different> | subscribe ibis-users <optional e-mail address, if different> | unsubscribe ibis <optional e-mail address, if different> | unsubscribe ibis-users <optional e-mail address, if different> | |or e-mail a request to ibis-request@eda-stds.org. | |IBIS reflector archives exist under: | | http://www.eda-stds.org/pub/ibis/email_archive/ Recent | http://www.eda-stds.org/pub/ibis/users_archive/ Recent | http://www.eda-stds.org/pub/ibis/email/ E-mail since 1993
This archive was generated by hypermail 2.1.8 : Fri Dec 19 2008 - 15:10:01 PST