[IBIS-Users] IBIS Correlation Issues on IV Part

From: Tan, Ai-Heong <Ai-Heong.Tan@spansion.com>
Date: Fri Aug 15 2014 - 13:58:13 PDT
Hi EXPERTS,

Currently, I am performing IV curve measurement for a flash package (SOIC16 package).
I am using Source Measurement Unit (SMU Keithley 4200), DC Power Supply (Keithley 2230-30-1), Arbitrary  Waveform Generator (AWG Tektronix 5200C), and a 4 layer PCB breakout board for the setup.
The flash package was placed in a socket which soldered on top of the PCB breakout board. Then, the AWG is used to perform the programming/triggering on the flash device in order to generate a HIGH / LOW output waveform.
The SMU is connected to the output of the flash device and I sweep the voltage from -0.7V - 3.6V (operating region of the flash).
Please refer to the figure below for the IV curve measurement on the Pullup and Pulldown which I overlapped it with the IBIS model result.
I observed there were an instantaneous open happened at the region 1.8 - 3.3V for the Pulldown result of each IO.
May I know why this happened and how to solve it.
Besides, can everyone please advise on the quality of the IBIS model and any constructive suggestions/comments for improvement are appreciated sincerely.
Thanks and I hope to hearing from you soon.

[cid:image001.png@01CFB6EA.25EBDA10][cid:image002.jpg@01CFB6EA.AE8CF6B0]



Best Regards,
Ai Heong


-- 
This message has been scanned for viruses and
dangerous content by MailScanner, and is
believed to be clean.



--------------------------------------------------------------------
|For help or to subscribe/unsubscribe, e-mail mikelabonte@eda-stds.org
|or ibis-request@eda-stds.org
|
|IBIS reflector archives exist under:
|
|  http://www.eda-stds.org/ibis/email_archive/ Recent
|  http://www.eda-stds.org/ibis/users_archive/ Recent
|  http://www.eda-stds.org/ibis/email/         E-mail since 1993
image001.png
image002.jpg
Received on Fri Aug 15 13:59:25 2014