[IBIS] maximum current flows

From: lau yy <tok47_at_.....>
Date: Tue May 31 2005 - 22:41:05 PDT
Dear ALL,
 
Recently, I have faced the maximumcurrent flows warning. Do anyone know what actual the main cause?
 
I suspect is the R package/ R _pin value that is too small. I try to replace some larger value
and simulate again. I found that the problems gone. Is it that mean the problem cause by the R?
 
Below are the message the shown after use ibischk3.
 
WARNING - Model 'A22': Extreme currents present in TYP GND_Clamp VI Curve
(-23.94A @ -1.5V)
 WARNING - Model 'A22': Extreme currents present in MIN GND_Clamp VI Curve
(-26.24A @ -1.5V)
 WARNING - Model 'A22': Extreme currents present in MAX GND_Clamp VI Curve
(-22.08A @ -1.5V)
 WARNING - Model 'OEB': Extreme currents present in TYP GND_Clamp VI Curve
(-15.92A @ -1.5V)
 WARNING - Model 'OEB': Extreme currents present in MIN GND_Clamp VI Curve
(-17.48A @ -1.5V)
 WARNING - Model 'OEB': Extreme currents present in MAX GND_Clamp VI Curve
(-14.66A @ -1.5V)
 WARNING - Model 'CLK': Extreme currents present in TYP GND_Clamp VI Curve
(-3.133e+11A @ -1.5V)
 WARNING - Model 'CLK': Extreme currents present in MIN GND_Clamp VI Curve
(-4.438e+10A @ -1.5V)
 WARNING - Model 'CLK': Extreme currents present in MAX GND_Clamp VI Curve
(-3.558e+12A @ -1.5V)
 
Any comments on this?
 
 
Rdgs
YYLAU
----------------------------------------------------------------- |For help or to subscribe/unsubscribe, email majordomo@eda.org |with the appropriate command message(s) in the body: | | help | subscribe ibis | subscribe ibis-users | unsubscribe ibis | unsubscribe ibis-users | |or email a request to ibis-request@eda.org. | |IBIS reflector archives exist under: | | http://www.eda.org/pub/ibis/email_archive/ Recent | http://www.eda.org/pub/ibis/users_archive/ Recent | http://www.eda.org/pub/ibis/email/ E-mail since 1993 Received on Tue May 31 22:41:07 2005

This archive was generated by hypermail 2.1.8 : Tue May 31 2005 - 22:42:07 PDT