Dear ALL,
Recently, I have faced the maximumcurrent flows warning. Do anyone know what actual the main cause?
I suspect is the R package/ R _pin value that is too small. I try to replace some larger value
and simulate again. I found that the problems gone. Is it that mean the problem cause by the R?
Below are the message the shown after use ibischk3.
WARNING - Model 'A22': Extreme currents present in TYP GND_Clamp VI Curve
(-23.94A @ -1.5V)
WARNING - Model 'A22': Extreme currents present in MIN GND_Clamp VI Curve
(-26.24A @ -1.5V)
WARNING - Model 'A22': Extreme currents present in MAX GND_Clamp VI Curve
(-22.08A @ -1.5V)
WARNING - Model 'OEB': Extreme currents present in TYP GND_Clamp VI Curve
(-15.92A @ -1.5V)
WARNING - Model 'OEB': Extreme currents present in MIN GND_Clamp VI Curve
(-17.48A @ -1.5V)
WARNING - Model 'OEB': Extreme currents present in MAX GND_Clamp VI Curve
(-14.66A @ -1.5V)
WARNING - Model 'CLK': Extreme currents present in TYP GND_Clamp VI Curve
(-3.133e+11A @ -1.5V)
WARNING - Model 'CLK': Extreme currents present in MIN GND_Clamp VI Curve
(-4.438e+10A @ -1.5V)
WARNING - Model 'CLK': Extreme
currents present in MAX GND_Clamp VI Curve
(-3.558e+12A @ -1.5V)
Any comments on this?
Rdgs
YYLAU
-----------------------------------------------------------------
|For help or to subscribe/unsubscribe, email majordomo@eda.org
|with the appropriate command message(s) in the body:
|
| help
| subscribe ibis