[IBIS] Clarification in pullup curve

From: Shrikant G Kadadevar - NSBG <Shrikant.G.Kadadevar_at_.....>
Date: Tue Sep 02 2008 - 04:33:42 PDT
Hello All,

Suppose I have the separate VCC for logic level and ESD clamp ie 1.8 and 
3.3.
In this case when calculating the pullup/PGclamp curve, what would be 
the relative voltage I should consider for curve.
That is my pullup curve would be VCC-V_sweep, what should be VCC?

Thanks,
Shrikant



-- 
This message has been scanned for viruses and
dangerous content by MailScanner, and is
believed to be clean.

--------------------------------------------------------------------
|For help or to subscribe/unsubscribe, e-mail majordomo@eda-stds.org
|with the appropriate command message(s) in the body:
|
|  help
|  subscribe   ibis       <optional e-mail address, if different>
|  subscribe   ibis-users <optional e-mail address, if different>
|  unsubscribe ibis       <optional e-mail address, if different>
|  unsubscribe ibis-users <optional e-mail address, if different>
|
|or e-mail a request to ibis-request@eda-stds.org.
|
|IBIS reflector archives exist under:
|
|  http://www.eda-stds.org/pub/ibis/email_archive/ Recent
|  http://www.eda-stds.org/pub/ibis/users_archive/ Recent
|  http://www.eda-stds.org/pub/ibis/email/         E-mail since 1993
Received on Tue Sep 2 04:45:52 2008

This archive was generated by hypermail 2.1.8 : Tue Sep 02 2008 - 04:46:57 PDT