Hi all, I am trying to validate an IBIS 5.0 model at 500Mbps with package parasitics (R, L, C for supply, ground and pad) and on-die RC decoupling. The issue is that the I-T waveforms are not matching when I add inductance to the ground terminal. When I remove the inductance on the ground terminal keeping the rest of the setup same, the I-T waveforms correlate. Has anyone come across this issue or any suggestions on rectifying the same? Thanks & Regards, Rinsha -- This message has been scanned for viruses and dangerous content by MailScanner, and is believed to be clean. -------------------------------------------------------------------- |For help or to subscribe/unsubscribe, e-mail mikelabonte@eda-stds.org |or ibis-request@eda-stds.org | |IBIS reflector archives exist under: | | http://www.eda-stds.org/ibis/email_archive/ Recent | http://www.eda-stds.org/ibis/users_archive/ Recent | http://www.eda-stds.org/ibis/email/ E-mail since 1993Received on Thu Apr 4 04:39:52 2013
This archive was generated by hypermail 2.1.8 : Thu Apr 04 2013 - 04:40:42 PDT